Total Hip Arthroplasty Using Proximal Porous Coating Stem with Distal Sleeve: Mid-Term Outcome

Author:

Saito M1,Takahashi KA1,Fujioka M1,Ueshima K1,Sakao K1,Inoue S2,Kubo T1

Affiliation:

1. Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan

2. Kyoto Prefectural Rehabilitation Hospital for the Disabled, Kyoto, Japan

Abstract

Purpose. To report mid-term results of total hip arthroplasty (THA) using the Opti-Fix Plus Hip System (Opti-Fix Hip), and to assess the correlations between peri-implant bone changes and the distal medullary occupancy rate. Methods. 11 men (13 hips) and 53 women (58 hips) aged 24 to 87 (mean, 61) years underwent THA using the Opti-Fix Hip, with a modular stem and a distal sleeve, and were followed up for a mean of 6.5 (range, 4.8–9.6) years. Clinical outcomes were evaluated using the Japanese Orthopaedic Association (JOA) hip score. Implant stability, bone changes around the implant, and the occupancy rate of the stem in the medullary space were examined radiologically. Bone changes around the implant were assessed based on the radiological evidence of a pedestal, osteolysis, stress shielding, and radiolucent lines. Results. The mean JOA score increased significantly after surgery and was maintained at the latest follow-up. Around the acetabular and femoral components respectively, 38 and 58 hips had radiolucent lines, whereas one and 54 hips developed osteolysis. A pedestal appeared in 21 hips and grade-III or higher stress shielding in 30 hips. Two hips showed loosening of the acetabular components, but none in the femoral components. Osteolysis around the stem was frequently observed in hips with poor distal medullary occupancy. Conclusion. Clinical and radiological outcomes of the Opti-Fix Hip were favourable. The low incidence of osteolysis in the distal stem suggests that the proximal circumferential porous coating was effective. Minor osteolysis around the proximal stem was frequently observed, indicating early excessive wear of the polyethylene liner. Its high distal medullary occupancy rate could inhibit stem micromotion and aseptic loosening.

Publisher

SAGE Publications

Subject

Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3