Similar radiological results with accelerometer-based navigation versus conventional technique in total knee arthroplasty

Author:

Moo Ing How1,Chen Jerry Yong Qiang1,Chau Dickson Hong Him1,Tan See Wei1,Lau Adrian Cheng Kiang1,Teo Yee Sze1

Affiliation:

1. Department of Orthopaedics Surgery, Changi General Hospital, Singapore, Singapore

Abstract

Background: The Zimmer iASSIST system is an accelerometer-based, portable navigation device for total knee arthroplasty (TKA) that does not require the use of a large console for alignment feedback as required in computer-assisted surgery. The purpose of this study was to determine the accuracy of the accelerometer-based system in component positioning and overall mechanical alignment. Methods: Two groups of 30 patients each with primary osteoarthritis underwent TKA using either conventional method or Zimmer iASSIST navigation in 2013 was retrospectively studied. Patients were matched according to body mass index (BMI), gender and age. A senior arthroplasty surgeon performed all the operation using the same surgical approach. Perioperative and post-operative regimens were the same. All patients had standardized radiographs performed post-operatively to determine the lower limb mechanical alignment and component placement. Results: There was no difference between the two groups for age, BMI, gender, side of operated knee and preoperative mechanical axis ( p > 0.05). There was no difference in the proportion of outliers for mechanical axis ( p = 0.38), coronal femoral angle ( p = 0.50), coronal tibia angle ( p = 0.11), sagittal femoral angle ( p = 0.28) and sagittal tibia angle ( p = 0.33). The duration of surgery, post-operative drop in haemoglobin level and transfusion incidence did not show statistically significant differences between the two groups ( p > 0.05). Conclusions: Our article showed that iASSIST was safe and remains a useful tool to restore mechanical axis. However, our data demonstrated no difference in lower limb alignment and component placement between the TKA that used accelerometer-based system and those that underwent conventional method.

Publisher

SAGE Publications

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3