Purpose. To evaluate the discrepancy between the anatomical axis of the distal femur of Japanese patients and the stem position of 5 types of femoral components. Methods. Lateral radiographs of 12 men and 88 women aged 31 to 83 (mean, 59) years with rheumatoid arthritis were evaluated. The discrepancy between the anatomical axis of the distal femur and the stem position of 5 types of femoral components (Nexgen LCCK, Press-Fit Condylar, Scorpio, Total Stabilizer, and Rotating Hinge) was determined by superimposing the template of each model over each lateral radiograph. Results. The anatomical axis varied widely among our patients, as did the stem position of the 5 femoral components. Stems of all 5 femoral components tended to be more posterior than the anatomical axis. The discrepancy was smallest in the Nexgen LCCK, followed by the Press-Fit Condylar components. It was >3 mm in the other 3 models. In 35% of the patients, none of the prosthesis could be placed in an appropriate position. Smaller-size prostheses appear necessary for the Japanese. Conclusion. The stem position should be an important factor guiding selection of the appropriate model. The currently available femoral components may not be appropriate for the Japanese. Prostheses with appropriately positioned stems for Japanese patients with rheumatoid arthritis should be developed.

Publisher

SAGE Publications

Subject

Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Comparative Demographics, ROM, and Function After TKA in Chinese, Malays, and Indians;Clinical Orthopaedics & Related Research;2013-05

2. Asian-Specific total knee system: 5-14 year follow-up study;BMC Musculoskeletal Disorders;2011-11-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3