Rotator Cuff Repair With a Novel Interpositional Allograft Augmentation

Author:

Forsythe Brian1ORCID,Gamsarian Vahram1,Mirle Vikranth1,Berlinberg Elyse J.2ORCID,Patel Harsh H.3,Swindell Hasani4,Yanke Adam B.1,Garrigues Grant E.1,Brusalis Christopher M.1

Affiliation:

1. Midwest Orthopaedics at Rush, Chicago, Illinois, USA

2. New York University Grossman School of Medicine, New York University Langone Medical Center, New York City, New York, USA

3. Rutgers New Jersey Medical School, Rutgers University, Newark, New Jersey, USA

4. Columbia University, New York–Presbyterian Brooklyn Methodist Hospital, Brooklyn, New York, USA

Abstract

Background: Nearly half a million rotator cuff repairs are performed annually in the United States. Rotator cuff healing occurs at the interface between the tendon and greater tuberosity, known as the enthesis. Given that a significant number of rotator cuff tears do not heal following surgical repair, multiple adjunctive strategies have been devised to improve the structural integrity of the repaired construct. Recently, a biphasic, demineralized allograft bone implant has been developed to improve enthesis healing. Indications: Relative indications for use of tissue augmentation include greater tuberosity osteopenia, revision rotator cuff surgery, attenuated rotator cuff tissue quality, and massive rotator cuff tears. Relative contraindications include a history of infection and recent immunosuppression. Technique Description: Following preparation of the footprint with an arthroscopic burr, two triple-loaded PEEK suture anchors were placed along the medial aspect of the greater tuberosity. Sutures were then passed through the rotator cuff tendon in a horizontal mattress configuration, and each pair of suture limbs were tied along the medial row. To aid in arthroscopic passage, the biphasic graft is folded longitudinally and clamped with a curved hemostat. The graft is loaded into an arthroscopic cannula and both are delivered simultaneously through a lateral arthroscopic portal. Two 18-gauge spinal needles are placed percutaneously to fix the allograft in the desired position. Subsequently, double-row transosseous-equivalent rotator cuff repair with standard techniques is done, which provides sufficient stability to the graft. Discussion: In a series of 192 patients who underwent arthroscopic rotator cuff repair augmented with a similar bioinductive collagen implant, patients demonstrated significant improvement in patient-reported outcomes at 1 year postoperatively. Moreover, a meta analysis published in 2022 demonstrated a significantly reduced retear rate among patch-augmented rotator cuff repairs as compared to isolated rotator cuff repairs. Conclusion: Tissue augmentation can be performed efficiently and reproducibly to promote biologic healing of arthroscopic rotator cuff repairs. The specific biphasic cancellous allograft presented in this video may be a viable treatment adjunct in the setting of deficient greater tuberosity bone stock, revision cases, or impaired native enthesis healing; however, further research is needed to assess clinical outcomes associated with its use. Patient Consent Disclosure Statement: The author(s) attests that consent has been obtained from any patient(s) appearing in this publication. If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.

Publisher

SAGE Publications

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3