All Arthroscopic Suprapectoral Biceps Tenodesis

Author:

McCahon Joseph A. S.1,Albana Mohamed F.2,Szukics Patrick F.1,McMillan Sean3

Affiliation:

1. Department of Orthopaedic Surgery, Jefferson Health–New Jersey, Stratford, New Jersey, USA

2. Department of Orthopaedic Surgery, Inspira Health System, Vineland, New Jersey, USA

3. Department of Orthopaedic Surgery, Virtua Health, Burlington, New Jersey, USA

Abstract

Background: Biceps tendinopathy can have significant clinical manifestations in active patients. Failure to achieve resolution of symptoms through nonsurgical modalities oftentimes results in surgical intervention. The 2 most common surgical treatment options for tendinopathy of the long head of the biceps tendon (LHBT) are tenotomy and tenodesis. Both modalities have shown efficacy within the literature; however, tenodesis of the LHBT has many advantages to tenotomy. Indications: Subgroove tenodesis eliminates the potential pain generation within the bicipital groove. Despite recent proof of clinical equivalence in open versus arthroscopic tenodesis, there has been increasing interest in all-arthroscopic biceps tenodesis techniques in hopes of minimizing surgical exposure, decreasing the rate of potential neurovascular compromise, and decreasing the time to recovery. Technique: We present an all-arthroscopic technique for a subgroove biceps tenodesis using a unicortical tensionable button. The proximal biceps anchor is held in place at its insertion site with a spinal needle to prevent retraction. The lateral portal is redirected into the subdeltoid space. A novel suprapectoral biceps portal, called the Willingboro portal, is placed percutaneously 2 cm above the pectoralis tendon. Onlay fixation of the LHBT is performed proximal to the pectoralis major muscle insertion using a unicortical button. Postoperative protocol is similar to other fixation constructs. Results: Numerous arthroscopic biceps tenodesis techniques have been described with good success; however, an all-arthroscopic suprapectoral tenodesis is attractive to many reasons. The unicortical button construct shows similar load to failure strength as the bicortical button construct, both of which are greater than all other constructs described in the literature. Discussion/Conclusion: Arthroscopic subgroove biceps tenodesis using a unicortical button technique is a viable option that avoids the complications associated with an open axillary incision as well as persistent groove pain. Anchoring the biceps tendon prior to tenotomy allows for preservation of tendon length, limiting the complications associated with tendon retraction with anticipated improvement in patient-reported outcomes. The unicortical button is known to have a similar strength profile as the bicortical button technique, which is greater than other techniques described in the literature. Future studies should be aimed at assessing long-term patient-reported outcomes. Patient Consent Disclosure Statement: The author(s) attests that consent has been obtained from any patient(s) appearing in this publication. If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3