Affiliation:
1. Department of Industrial Engineering and Operations Research University of Massachusetts—Amherst
Abstract
Two experiments were conducted to evaluate the effects on applied force of structural design parameters and of feedback conditions inherent in the aesthetic overlay of membrane switch touchpads. In the first experiment which evaluated structure, 12 males and 12 females keyed 100 4-digit sequences into a computer using 6 of a total of 12 touchpads which differed in membrane ply thickness, spacer thickness, and spacer aperture diameter. The same task was completed by nine males and nine females in the second experiment, which evaluated feedback conditions inherent in flat, embossed, domed, embossed with dome, flat with escutcheon, and domed keycap aesthetic overlays. The results have important implications for the methods used for life-testing membrane switch touchpad devices and for the design of touchpads for minimizing user fatigue in extended-use keying applications.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Functions;Ergonomics in Design: The Quarterly of Human Factors Applications;1994-10