Prospective Evaluation of Adhesion Formation and Shrinkage of Intra-Abdominal Prosthetics in a Rabbit Model

Author:

Harrell Andrew G.1,Novitsky Yuri W.1,Peindl Richard D.1,Cobb William S.1,Austin Catherine E.1,Cristiano Joseph A.1,Norton James H.1,Kercher Kent W.1,Heniford B. Todd1

Affiliation:

1. Carolinas Hernia Center, Division of Gastrointestinal and Minimally Invasive Surgery, Department of General Surgery, Carolinas Medical Center, Charlotte, North Carolina

Abstract

Laparoscopic ventral hernia repair requires an intraperitoneal prosthetic; however, these materials are not without consequences. We evaluated host reaction to intraperitoneal placement of various prosthetics and the functional outcomes in an animal model. Mesh (n = 15 per mesh type) was implanted on intact peritoneum in New Zealand white rabbits. The mesh types included ePTFE (DualMesh®), ePTFE and polypropylene (Composix®), polypropylene and oxidized regenerated cellulose (Proceed®), and polypropylene (Marlex®). Adhesion formation was evaluated at 1, 4, 8, and 16 weeks using 2-mm mini-laparoscopy. Adhesion area, adhesion tenacity, prosthetic shrinkage, and compliance were evaluated after mesh explantation at 16 weeks. DualMesh® had significantly less adhesions than Proceed®, Composix®, or Marlex® at 1, 4, 8, and 16 weeks ( P < 0.0001). Marlex® had significantly more adhesions than other meshes at each time point ( P < 0.0001). There were no statistically significant differences in adhesions between Proceed® and Composix® meshes. After mesh explantation, the mean area of adhesions for Proceed® (4.6%) was less than for Marlex® (21.7%; P = 0.001). The adhesions to Marlex® were statistically more tenacious than the DualMesh® and Composix® groups. Overall prosthetic shrinkage was statistically greater for DualMesh® (34.7%) than for the remaining mesh types ( P < 0.01). Mesh compliance was similar between the groups. Prosthetic materials demonstrate a wide variety of characteristics when placed inside the abdomen. Marlex® formed more adhesions with greater tenacity than the other mesh types. DualMesh® resulted in minimal adhesions, but it shrank more than the other mesh types. Each prosthetic generates a varied host reaction. Better understanding of these reactions can allow a suitable prosthetic to be chosen for a given patient in clinical practice.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 59 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Colon diverticulosis adherent to mesh plug migration after laparoscopic hernia repair: A case study and review of literature;International Journal of Surgery Case Reports;2021-10

2. Biomaterials and Scaffolds in Stem Cell Therapy;Stem Cells in Veterinary Science;2021

3. Mesh migration following abdominal hernia repair: a comprehensive review;Hernia;2019-01-30

4. Mesh;Shackelford's Surgery of the Alimentary Tract, 2 Volume Set;2019

5. Robotic Technique for Intraperitoneal Onlay Mesh (IPOM);The SAGES Manual of Hernia Surgery;2018-11-24

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3