Abstract

Background The efficacy of microwave ablation in treating hepatic tumors requires advanced ultrasound skills. Failure of proper technique has the potential for either under- or over-treatment and possible harm to the patient. Emprint SX™ navigation provides surgeons with intra-operative, real-time navigation through augmented reality localization of the ablation antenna and the expected ablation zone. We hypothesize that incorporating this technology leads to improved targeting and optimizes ablation coverage. This study utilizes a simulated model to evaluate ablation outcomes using Emprint SX™ navigation vs standard ultrasound. Methods Surgical residents and faculty were recruited from a single institution. Using a novel tumor ablation simulator, participants performed ablations via 2 modes: standard ultrasound guidance (STD) and Emprint SX™ navigation (NAV). Primary outcome was the percentage of under-ablation. Secondary outcomes included percentage of over-ablation, time to complete trial, and number of attempts to position antenna. Results 281 trials were performed by fifteen participants, with 47% female and 60% novice ablationists. Under-ablation volume decreased by a mean of 16.3% (SEM ±12.9, P < .001) with NAV compared to STD. Over-ablation volume decreased by a mean of 14.0% (±8.2, P < .001). NAV time was faster by a mean of 32 seconds (±24.9, P < .001) and involved fewer antenna placement attempts by a mean of 1.3 (±1.0, P < .001). For novice ablationists, all outcomes were improved with NAV and novices saw larger improvements compared to experienced ablationists ( P = .018). Discussion In a simulated model, NAV improves ablation efficacy and efficiency, with novices gaining the greatest benefit over standard ultrasound.

Funder

Medtronic

Publisher

SAGE Publications

Subject

General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3