Anatomical Suitability of the Aortic Arch Arteries for a 3-Inner-Branch Arch Endograft

Author:

Spanos Konstantinos1ORCID,Haulon Stephan2,Eleshra Ahmed1ORCID,Rohlffs Fiona1ORCID,Tsilimparis Nikolaos1,Panuccio Giuseppe1ORCID,Kölbel Tilo1ORCID

Affiliation:

1. German Aortic Center Hamburg, Department of Vascular Medicine, University Heart & Vascular Center, Hamburg, Germany

2. Aortic Centre, Groupe Hospitalier Paris Saint Joseph, Hôpital Marie Lannelongue, Université Paris Saclay, Le Plessis-Robinson, Paris, France

Abstract

Purpose: To analyze aortic arch anatomy of patients who were already treated with a 2-inner-branch arch endograft (2-IBAE) in order to assess the anatomical suitability of the supra-aortic arteries as target vessels for a 3-IBAE. Materials and Methods: Three different configurations of the Cook Zenith Arch endograft were designed with distances of 110 mm (model 1), 90 mm (model 2), and 70 mm (model 3) between the orifices of the first and third inner branches. Preoperative measurements of the aortic arch anatomy from 104 consecutive patients treated electively with custom-made 2-IBAEs at 2 European centers between 2014 and 2019 were analyzed. A previously described standard methodology with a planning sheet was used. Data and measurements included the treatment indication for the aortic arch pathology, the type of landing zone, the type of arch, and the inner and outer lengths of the ascending aorta from the sinotubular junction to the innominate artery (IA). Additionally, the diameters and clock positions of the IA, left common carotid artery (LCCA), and left subclavian artery (LSA) were assessed, along with the distances between the IA and the LCCA, the IA and the LSA, and the distal landing zone. Results: Type I was the most common arch configuration (75/104, 72%). The mean clock positions were 12:30±00:28 for the IA, 12:00±00:23 for the LCCA, and 12:15±00:29 for the LSA. The mean diameters were 14.2±2.2 mm for the IA, 8.8±1.8 mm for the LCCA, and 10.5±2 mm for the LSA. The mean distances between the IA and LCCA and between the IA and LSA were 14.7±5.8 mm and 33±9.4 mm, respectively. Model 2 (branch distance 90 mm) had the highest suitability (79%), while models 1 and 3 showed suitability rates of 73% and 68%, respectively. The most frequent exclusion criterion in all models was the diameter of the LSA, followed by the IA to LSA distance. Conclusion: The suitability for a 3-IBAE among patients who had a 2-IBAE implanted is high, favoring a 90-mm distance between the retrograde LSA branch and baseline.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3