Transcervical Carotid Stenting With Dynamic Flow Reversal Demonstrates Embolization Rates Comparable to Carotid Endarterectomy

Author:

Plessers Maarten12,Van Herzeele Isabelle2,Hemelsoet Dimitri3,Patel Nikil4,Chung Emma M. L.4,Vingerhoets Guy1,Vermassen Frank2

Affiliation:

1. Department of Experimental Psychology, Ghent University, Ghent, Belgium

2. Department of Thoracic and Vascular Surgery, Ghent University Hospital, Ghent, Belgium

3. Department of Neurology, Ghent University Hospital, Ghent, Belgium

4. Department of Cardiovascular Sciences, University of Leicester, UK

Abstract

Purpose: To evaluate a series of patients treated electively with carotid endarterectomy (CEA), transfemoral carotid artery stenting with distal filter protection (CASdp), and transcervical carotid stenting with dynamic flow reversal (CASfr) monitored continuously with transcranial Doppler (TCD) during the procedure to detect intraoperative embolization rates. Methods: Thirty-four patients (mean age 67.6 years; 24 men) with significant carotid stenosis underwent successful TCD monitoring during the revascularization procedure (10 CEA, 8 CASdp, and 16 CASfr). Ipsilateral microembolic signals were segregated into 3 phases: preprotection (until internal carotid artery cross-shunted or clamped if no shunt was used, filter deployed, or flow reversal established), protection (until clamp/shunt was removed, filter retrieved, or antegrade flow reestablished), and postprotection (after clamp/shunt or filter removal or restoration of normal flow). Results: CASdp showed higher embolization rates than CEA or CASfr in the preprotection phase (p<0.001). In the protection phase, CASdp was again associated with more embolization compared with CEA and CASfr (p<0.001). In the postprotection phase, no differences between the revascularization therapies were observed. CASfr and CEA did not show significant differences in intraoperative embolization during any of the phases. Conclusion: TCD recordings demonstrated a significant reduction in embolization to the brain during transcervical carotid artery stent placement with the use of dynamic flow reversal compared to transfemoral CAS using distal filters. No significant differences in microembolization could be detected between CEA and CASfr. The observed lower embolization rates and lack of adverse events suggest that transcervical CAS with dynamic flow reversal is a promising technique and may be the preferred method when performing CAS.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3