Abstract

Introduction: Thoracic endovascular aortic repair (TEVAR) in chronic dissection is associated with a risk for distal stent-graft-induced new entry (dSINE) in up to a quarter of cases. We assess the mid-term outcome of a novel dissection-specific stent-graft (DSSG), which is a custom-made device based on the Cook Alpha platform, with a modified graft design and a distal endovascular elephant trunk without any supporting stent to reduce the radial force on the dissection membrane at the distal landing zone. Methods: A retrospective single-center study of chronic dissection patients at high risk of dSINE who received an elective endovascular repair with DSSG from January 2017 to June 2023. The primary outcome is Kaplan-Meier (KM) estimated freedom from dSINE during follow-up. Secondary outcomes included technical success, aortic remodeling, and anatomical evaluation of the distal landing zone in cases with dSINE during follow-up versus those without. Results: Thirty patients (24 males) with a median age of 66 years [range=31-78] underwent elective TEVAR with the DSSG. The majority, n=27 (90%), had previous aortic repair; 7 (23%) had established connective tissue disease, and 6 (20%) had established dSINE after previous stent-graft implantation as an indication for TEVAR. Technical success was achieved in n=29 (97%). Median follow-up was 38.5 months (4.3-76.4), and KM estimated freedom from dSINE at 1 and 3 years was 95.6% (SE 0.043) and 89% (SE 0.081), respectively Four cases developed dSINE during follow-up. The median distance from the distal stent-graft to the coeliac trunk was 74mm (range=18-123) in the dSINE group versus 26mm (range=0-74) in the non-dSINE group (p=0.049). Median proximal tangential aortic angulation in the distal landing zone was 38.5° (range=26°-50°) in the dSINE group compared to 21° (range=3-61°) in the non-dSINE group (p=0.052). Conclusions: The Use of a novel DSSG with low radial force for TEVAR in the setting of chronic dissection is safe and feasible, with remodeling outcomes comparable with standard TEVAR. The reduced distal radial force in the DSSG does not eliminate the risk for dSINE over time, with new entries occurring, particularly in cases where the distal landing zone is in a tortuous aortic segment and not close to the coeliac trunk. Clinical Impact Using the novel dissection-specific stent-graft with reduced radial force is safe and feasible but does not completely eliminate the risk of dSINE occurring over time. The exact positioning of the distal stent-graft in a straight aortic segment, close to the coeliac trunk, may be of importance to further mitigate the risk.

Publisher

SAGE Publications

Reference11 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3