Affiliation:
1. Liverpool Vascular and Endovascular Service, Royal Liverpool University Hospital, Liverpool, UK
Abstract
Purpose: To present a case of aneurysm disruption during endovascular sealing of a ruptured abdominal aortic aneurysm. Case Report: A 91-year-old woman presented with a ruptured abdominal aortic aneurysm. Her aneurysm morphology was unsuitable for standard or fenestrated endovascular repair, whereas open repair was considered to have an increased perioperative risk owing to multiple comorbidities. The Nellix endovascular sealing system was used. The balloon-expandable stent-grafts were deployed, but in the presence of aneurysm rupture, it was decided not to prefill the endobags with saline. The patient developed hypotension during endobag filling, which resolved once target pressure was reached. The procedure was completed uneventfully, and the completion angiogram revealed no endoleak. The time from guidewire insertion to completion angiogram was 24 minutes. Over the following days, she developed a gradual drop in hemoglobin, and computed tomographic angiography revealed an increased retroperitoneal hematoma and pronounced disruption of the calcified rim of the aortic sac compared to the preoperative imaging. She was managed with supportive treatment, demonstrating remarkable progress. She remains in good health 4 months later. Conclusion: Endovascular sealing can be used in patients with ruptured abdominal aortic aneurysm. Intraoperative endobag saline prefill should be avoided to minimize the risk of aortic wall disruption.
Subject
Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献