Efficacy of Endovascular Repair Using Single Left Common Carotid Artery Stent Combined with Castor Single-Branched Stent-Graft in the Treatment of Regional Diseases of Zone 2 of the Aorta

Author:

Fang Jie1,Tian Chen1ORCID,Chen Dong1ORCID,Luo Mingyao1ORCID,Fang Kun1ORCID,Tian Chuan2,Shu Chang13ORCID

Affiliation:

1. Department of Vascular Surgery, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Centre for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

2. Department of Cardiac Surgery, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Centre for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

3. Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China

Abstract

Purpose: To observe the short-term efficacy of thoracic endovascular aortic repair (TEVAR) using a single left common carotid artery chimney stent combined with a Castor single-branched stent-graft (SC-TEVAR) in the treatment of zone 2 (Z2) aortic diseases. Materials and Methods: To conduct a retrospective analysis of 20 patients with Z2 aortic diseases who were treated in our department from June 2021 to April 2022. The lesions included true aortic degenerative aneurysms with diameter ≥5.0 cm and penetrating aortic ulcers with depth >1.0 cm or basal width >2.0 cm. All 20 patients accepted the SC-TEVAR treatment, which was a new hybrid method to assure the flow of the left common carotid artery (LCCA) and left subclavian artery (LSA). This method was defined as a concomitant chimney stent for LCCA and a Castor single-branched stent graft for the aorta and LSA. The baseline data and intraoperative data were collected to evaluate the safety and efficacy of this method. The patency of the target blood vessel and any associated complications were evaluated at 1 and 6 months postoperatively, to analyze the safety and efficacy of this new method. Results: After discharge from the hospital, all patients were followed up by a specific follow-up team. At 6 monthly follow-up period, there were no cardiac events, stroke, hemiplegia, type I endoleak, type II endoleak, proximal stent graft-induced new entries, distal stent graft-induced new entries, wound infection, or bleeding. Only 1 patient developed an inguinal wound hematoma and got conservative treatment. Importantly, no patients developed stenosis or occlusion of the LCCA or LSA. The patency of branched arteries was 100%. The technical success rate was 90%. Conclusion: SC-TEVAR appears to be a new and relatively simple, safe, and effective treatment for Z2 aortic diseases. Clinical Impact This was a single-center retrospective cohort study. A total of 20 patients with zone 2 aortic diseases accepted a new hybrid surgical method named SC-TEVAR. This method was not complicated and could be finished with only 3 peripheral artery exposure. The result showed no mortality, 100% patency of the branch artery, and 90% of technical success in 6 months of follow-up time. SC-TEVAR showed a satisfactory result in this retrospective study and could be promoted as an easy method to treat zone 2 aortic diseases.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3