Immediate Change in Suprarenal Neck Angulation After Endovascular Aneurysm Repair

Author:

Georgakarakos Efstratios1,Ioannou Christos V.2,Trellopoulos George3,Kontopodis Nikolaos2,Papachristodoulou Athanasia4,Torsello Giovanni5,Bisdas Theodosios5

Affiliation:

1. Department of Vascular Surgery, “Democritus” University of Thrace, University Hospital of Alexandroupolis, Greece

2. Department of Vascular Surgery, University Hospital of Heraklion, University of Crete Medical School, Heraklion, Greece

3. First Surgical Clinic, General Hospital “G. Papanikolaou” Exohi, Thessaloniki, Greece

4. Laboratory of Radiology, “Euromedic” Medical Center, Thessaloniki, Greece

5. Department of Vascular Surgery, St. Franziskus Hospital, and University Clinic of Münster, Germany

Abstract

Purpose: To compare the immediate suprarenal neck angulation change between the Ovation stent-graft, with its inflatable sealing rings, and a stent-graft with a conventional sealing mechanism. Methods: A case-control study was conducted in which 30 consecutive patients (mean age 67 years; all men) with abdominal aortic aneurysm (AAA) treated with the Ovation stent-graft (group O) were retrospectively compared with 24 patients (mean age 77 years; all men) contemporaneously treated with the Endurant stent-graft (group E) at 3 high-volume tertiary vascular centers. The variables recorded were the aortic neck length, preoperative and postoperative angulation, minimum and maximum diameters of the infrarenal neck, as well as the maximum AAA diameter. All patients had undergone preoperative and postoperative (within 30 days) computed tomographic angiography. Multiple regression analysis compared the relative contribution to neck angulation change of each geometric parameter and the type of endograft. Data are presented as the mean ± standard deviation. Results: The mean preoperative suprarenal neck angulation in group O was 23.2°±18.0° compared with 23.8°±22.9° in group E ( t test, p=0.91). The neck lengths were 29.2±14.6 and 23.2±11.0 mm in groups O and E, respectively (p=0.1). Similarly, the minimum and maximum neck diameters were 22.4±2.6 and 25±3.5 mm, respectively, in group O vs 23.3±3.6 mm and 27.0±5.7 mm, respectively, in group E (p=0.3 and 0.12, respectively). The maximum transverse diameters of the AAA in the 2 groups were comparable, that is, 57.0±9.0 mm in group O vs 53.2±11.1 mm in group E (p=0.17). The Ovation stent-graft caused greater decrease in the aortic neck angulation postoperatively compared with the Endurant device (13.2°±16.1° vs 6.1°±5.9°, p=0.04). Multiple regression analysis revealed that preoperative neck angulation (β coefficient 0.37, p<0.001) and the type of endograft (β coefficient −7.91, p=0.01) had significant influence on the postoperative neck angulation change. The intraclass correlation coefficient ranged from 0.951 to 0.990 for the preoperative measurements and from 0.911 to 0.999 for the postoperative measurements for each examiner or the total of estimates at the measurement time points. Conclusion: The Ovation stent-graft induces greater postoperative reduction in the AAA neck angulation compared to an endograft with stent-supported graft seal. Expanded research to infrarenal angle as well to greater angles and correlation to clinical events is justified.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司