Affiliation:
1. Department of Vascular Surgery, Singapore General Hospital, Singapore
2. The Vascular and Endovascular Clinic, Gleneagles Medical Centre, Singapore
3. Health Services Research Center, SingHealth, Singapore
Abstract
Purpose: This is a prospective study to investigate the clinical outcomes of using noncompliant balloons in lower limb angioplasty for chronic limb threatening ischemia (CLTI). Materials and Methods: This is a prospective single-center cohort study performed at a local tertiary hospital in Singapore. Consecutive patients who underwent lower limb angioplasty for CLTI using a noncompliant balloon catheter were enrolled if they were aged 40 years and above, presented with CLTI Rutherford grade 4 to 6, and had TASC C or D lesions in the lower limb vessels that were at least 100mm in length. Patient demographics, Rutherford grading, lesion characteristics, complications, and follow-up data were collected and analyzed. The primary outcomes were 30-day freedom from major adverse events, amputation-free survival (AFS) at 12 months, and freedom from clinically driven target lesion revascularization (cdTLR) at 12 months. Secondary outcomes included clinical success and target lesion primary patency (TLPP) at 12 months. Amputation-free survival, freedom from cdTLR, and TLPP were calculated by Kaplan-Meier analysis. Results: From May 2020 to December 2021, 50 patients (50 limbs) were enrolled. 43 (86%) patients had diabetes mellitus, while 12 patients (24%) had end-stage renal failure. 85 lesions were treated, including 59 (69.4%) below-the-knee (BTK) lesions. All the lesions were TASC C (n=45, 52.9%) or TASC D (n=40, 47.1%) lesions. Mean lesion length was 231.4±116.2mm. Technical success rate was 96.5%. No patients were lost to follow-up. Median follow-up duration was 282 days (IQR: 31-390 days). One patient died on day 26 due to an acute myocardial infarction. Two patients had groin hematomas postprocedure, both of which were treated conservatively. AFS, freedom from cdTLR, and TLPP at 12 months postprocedure was 70.0% (95% confidence interval [CI]: 58.4%-83.9%), 90.1% (95% CI: 83.4%-97.4%), and 61.1% (95% CI: 50.7%-73.6%), respectively. Conclusion: Early results have shown that the use of a high-pressure, noncompliant balloon is effective in lower limb angioplasty for CLTI in a highly challenging group of patients with a high prevalence of long BTK disease. Good vessel patency and limb salvage rates can be achieved, with a low complication rate. We await more long-term outcomes on vessel patency. Clinical Impact There are many devices in the market for use in lower limb angioplasty. However, many of them come with an increased financial cost, procedural time and procedural difficulty. We report our prospective results with the exclusive use of a high pressure, non-compliant balloon, in a challening group of patients with a high prevalence of diabetes and end stage renal failure, achieving amputation free surival at 6 and 12 months post-procedure of 84.0% and 70.0% respectively. The use of non-compliant balloon is technically easy and does not add additional steps compared to a standard POBA procedure, thus limiting costs. We believe this article can be a push factor for clinicians to consider the use of these high pressure, non-compliant balloons in their patient care.