The AneuRx Stent-Graft since FDA Approval: Single-Center Experience of 230 Cases

Author:

Ramaiah Venkatesh G.1,Westerband Alex1,Thompson Charles1,Ravi Rajagopalan1,Rodriguez Julio A.1,DiMugno Leanne1,Shafique Shoaib1,Olsen Dawn1,Diethrich Edward B.1

Affiliation:

1. Department of Cardiovascular and Endovascular Surgery, Arizona Heart Institute and Arizona Heart Hospital, Phoenix, Arizona, USA

Abstract

Purpose: To compare a single-center experience with the AneuRx stent-graft system before and after FDA approval to results from the multicenter phase II clinical trial. Methods: The medical records of 230 consecutive patients (218 men; mean age 74 years) undergoing AneuRx stent-graft implantation for abdominal aortic aneurysm (AAA) exclusion since September 1999 were reviewed to collect patient characteristics, aneurysm morphology, procedure variables, perioperative morbidity, mortality, and short-term outcome. These data were compared to the 30 patients treated at our institution during the AneuRx phase II clinical trial and to the overall multicenter trial data. Stent-graft difficulty was categorized from 1 (straight neck and access of appropriate size) to 4 (proximal neck <10 mm long or angulated >60° and/or difficult access) based on aneurysm morphology. Results: Data from the 30 patients enrolled in the phase II trial at our institution were comparable in terms of patient characteristics and procedure variables to patients treated after FDA approval and to the multicenter data. However, the proportion of cases involving aneurysms with a more complex morphology (levels 3 and 4) rose 22% after FDA approval, reflecting a change in referral patterns. Our postoperative endoleak and morbidity rates increased nonsignificantly with respect to our own phase II experience (17% versus 6%, 18% versus 11%, respectively);however, they were not significantly different from the multicenter data. Reintervention was performed in 15 of 38 endoleak cases, mostly type I. Only 5 (2.1%) cases had a persistent endoleak at the time of discharge. Conclusions: Since FDA approval of the AneuRx device, our endovascular practice has changed toward the management of increasingly more complex AAAs. Although we are attempting more challenging cases, we are able to maintain similarly high short-term success rates while offering stent-grafting to an increasing number of patients. These results suggest that more patients may be candidates for endoluminal graft placement than determined by the clinical trial selection criteria, provided that strict surveillance and long-term follow-up is maintained.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3