Abstract

Purpose: To preprocedurally determine the correct length of a nonbifurcated endovascular prosthesis for abdominal aortic aneurysm (AAA) repair using a computerized model. Methods: A computer program was implemented to calculate the optimal intraluminal course of nonbifurcated stent-grafts from spiral computed tomographic (CT) images of the aortic lumen reconstructed at 2.5, 5, and 10-mm slice thicknesses. The algorithm was tested using 10 phantoms fabricated from 150-mm-long, 10-mm-diameter copper rods that were bent into shapes mimicking different aortic configurations. Midpoint coordinates and rod diameters were determined from each CT image by 3 independent observers and served as input parameters to the program. The influence of the different CT reconstructions on the calculated lengths and possible observer dependence were assessed using calculated length estimation errors. Spiral CT images from 20 consecutive AAA patients scanned before stent-graft implantation were also processed to evaluate the algorithm under clinical conditions. Results: Length estimation errors of the phantoms depended on the degree of bending as well as on the CT reconstruction slice thickness but were observer independent. Maximum errors were 7% for the 10-mm slices, 3.5% for the 5-mm slices, and 1.2% for a 2.5-mm reconstruction. The mean longitudinal shortening of the aorta due to vessel tortuosity was 9.1% ± 4.8% among the 20 patients. Based on the results of the phantom study, errors of the calculated stent-graft lengths in patients were estimated to be ∼1% for a 5-mm CT reconstruction increment and <2% for a 10-mm increment. Conclusions: The proposed algorithm makes it possible to calculate noninvasively the correct length of straight stent-grafts under clinical conditions with a 1% to 2% error.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3