Abstract

Purpose: The purpose of the study is to ascertain endovascular aneurysm repair (EVAR) suitability in relation to stent-graft-specific instructions for use (IFU) in patients with a ruptured abdominal aortic aneurysm (RAAA). Materials and Methods: Using the preoperative computed tomography angiography (CTA), the aortic morphology of patients undergoing surgical repair of a RAAA in 2 Dutch hospitals between January 2014 and December 2019 was retrospectively assessed. Three-dimensional and central luminal line reconstructions were used. Anatomical suitability was defined according to the IFU of the stent graft system used. Results: Of 128 included patients, 112 (88%) were men and the mean age was 74.1 (SD=7.6) years. Anatomy within IFU for EVAR was present in 31 patients (24%). Overall, 94 patients (73%) were treated with open surgical repair (OSR) and 34 patients (27%) were treated with EVAR. Anatomy within IFU was present in 15 OSR patients (16%) and 16 EVAR patients (47%). In patients with anatomy outside of IFU, 90% (87/97) had unsuitable neck anatomy and 64% (62/97) had insufficient neck length. An unsuitable distal iliac landing zone was observed in 35 patients. Perioperative mortality was 27% (34/128), with no difference between OSR and EVAR (25/94 vs 9/34; p=0.989). Conclusion: Most RAAA patients in this series did not have aortic anatomy within IFU for EVAR, mainly due to insufficient neck length. However, whether anatomy outside of IFU equates to unsuitability for EVAR in an emergency setting remains a matter of debate and warrants further research. Clinical Impact The treatment of a ruptured abdominal aortic aneurysm can consist of endovascular repair or open repair. Retrospective anatomical assessment shows that most patients do not have anatomy inside the instructions for use for endovascular aneurysm repair, mainly due to insufficient neck length. Whether anatomy outside the instructions for use equates unsuitability for endovascular aneurysm repair remains a matter of debate.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3