Comparing Predictors Influencing Restenosis Following High-Dose Drug-Coated Balloon Angioplasty and Fluoropolymer-Based Drug-Eluting Stenting in Femoropopliteal Artery Lesions

Author:

Kurata Naoya12ORCID,Iida Osamu2ORCID,Takahara Mitusyoshi3,Asai Mitsutoshi2,Okamoto Shin2ORCID,Ishihara Takayuki2,Nanto Kiyonori2,Tsujimura Takuya2ORCID,Hata Yousuke2ORCID,Toyoshima Taku2ORCID,Higashino Naoko2,Nakao Sho2ORCID,Mano Toshiaki2

Affiliation:

1. Department of Clinical Engineering, Kansai Rosai Hospital, Amagasaki, Japan

2. Cardiovascular Center, Kansai Rosai Hospital, Amagasaki, Japan

3. Department of Diabetes Care Medicine, Graduate School of Medicine, Osaka University, Osaka, Japan

Abstract

Purpose: Despite widespread use of anti-restenosis devices, drug-coated balloons (DCBs) and drug-eluting stents (DESs), their appropriate use for femoropopliteal (FP) lesions has not been well investigated and the risk factors for restenosis have not been compared. To investigate risk factors associated with restenosis after endovascular therapy using DCB and DES for contemporary FP lesions. Materials and methods: This single-center, retrospective, observational study evaluated 378 FP lesions in 273 patients treated with DCB (278 lesions in 193 patients) or DES (120 lesions in 106 patients). The DCB used was high-dose DCB (IN.PACT, Admiral. Medtronic, Inc.) and DES was fluoropolymer-based DES (ELUVIA, Boston Scientific). Vessel preparation failure was defined as a residual stenosis of ≥50% and a dissection grade of D or greater on pre-dilatation angiography. The outcome measure was restenosis, and factors associated with restenosis in the DCB and DES groups were assessed using a Cox proportional hazards model. Results: The 2-year restenosis rate was not significantly different between the DCB and DES groups (29%±4% vs. 24%±5%, p=0.42). Interaction analysis demonstrated that popliteal lesions and plaque burden of ≥50% were restenosis-related factors for DES but not for DCB, whereas vessel preparation failure was a factor for DCB but not for DES (p<0.05). Vessel diameter of <6 mm and nodular calcification were risk factors in both groups (p<0.05). Conclusion: In contemporary FP lesions, smaller vessels and nodular calcification were shared restenosis-related factors for high-dose DCB and fluoropolymer-based DES. Popliteal lesions and plaque burden of ≥50% were restenosis-related factors for fluoropolymer-based DES and vessel preparation failure for high-dose DCB. Clinical Impact Shared and differential restenosis-related factors after endovascular therapy using high-dose drug-coated balloons (DCBs) and fluoropolymer-based drug-eluting stents (DESs) in contemporary femoropopliteal (FP) lesions are unclear. This single-center retrospective study included 378 FP lesions in 273 patients with lower-extremity arterial disease (high-dose DCB, 278 lesions in 193 patients; fluoropolymer-based DES, 120 lesions in 106 patients). Smaller vessels and calcified nodules were shared restenosis-related factors for both high-dose DCB and fluoropolymer-based DES, whereas popliteal lesions and plaque burden of ≥50% were restenosis-related factors for fluoropolymer-based DES and vessel preparation failure for high-dose DCB.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3