STABILISE (Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair) Is Associated With Good Anatomical Results on the Distal Thoracoabdominal Aorta at 2 Years

Author:

Maurin Arnaud12,Jacquier Alexis12,Bartoli Axel12,Barral Pierre-Antoine12,Vecchini Fabien12,Mancini Julien3ORCID,Omnes Virgile12,DeMasi Mariangela12,Piquet Philippe12,Gaudry Marine12ORCID

Affiliation:

1. Department of Radiology, APHM, Timone Hospital, Marseille, France

2. Timone Aortic Center, Department of Vascular Surgery, APHM, Timone Hospital, Marseille, France

3. Aix-Marseille Univ, APHM, INSERM, IRD Biostatistics Department, SESSTIM, BIOSTIC, Marseille, France

Abstract

Purpose: The aim of this comparative study was to evaluate the increased aortic diameter of the distal aorta after implementing the STABILISE technique in complicated type B aortic dissection (AD). Design: This is a comparative monocentric retrospective study. Materials and Methods: All patients who underwent an STABILISE procedure for complicated AD between 2018 and 2020 were included and compared with a historic cohort treated with thoracic endovascular aortic repair (TEVAR) alone. Aortic diameters were measured at 6 different levels on the thoracic and abdominal aorta. The primary end point was an increased aortic diameter at 1 and 2 years. The exclusion criterion was the absence of a computed tomography (CT) scan at 1 or 2 years. Results: A total of 55 patients were included: 24 in the TEVAR group and 31 in the STABILISE group. At the level of the stent graft, there was a decrease in aortic diameters in both groups without significant differences. At the level of the distal aorta, there was an increase in aortic diameters in both groups without significant differences. There were significantly more patients in the TEVAR group with an unfavorable increase in aortic diameter >5 mm of the distal aorta at 2 years than in the STABILISE group: 8 (33%) vs 1 (3%) (p=0.01). For chronic ADs, a significantly greater increase in aortic diameters of the distal aorta was observed in the STABILISE group. Conclusions: The STABILISE technique is technically feasible and potentially leads to decreased longer re-intervention rates; indeed, more patients had an unfavorable increase in aortic diameter in the TEVAR group than in the STABILISE group at 2 years. The high rate of long-term distal aortic aneurysm progression and reintervention after TEVAR alone suggests that this option is not sufficient to definitively treat these complex patients. Clinical Impact This article reported the results of stent assisted balloon induced intimal disruption and relamination (STABILISE) with a follow-up at 2 years. This is the first comparative study between STABILISE, which has emerged as a new technique inducing aortic remodeling and therefore better long-term outcome, and the standard technique TEVAR alone. STABILISE technique is associated with good results on the distal aorta at 2 years with a rate of patient with unfavorable aortic diameter evolution greater in TEVAR group compared to STABILISE group and could improve the long-term results on the distal aorta by inducing extensive aortic remodeling.

Publisher

SAGE Publications

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3