Feasibility and Safety of Renal and Visceral Target Vessel Cannulation Using Robotically Steerable Catheters During Complex Endovascular Aortic Procedures

Author:

Cochennec Frédéric1,Kobeiter Hicham1,Gohel Manj2,Marzelle Jean1,Desgranges Pascal1,Allaire Eric1,Becquemin Jean Pierre1

Affiliation:

1. Henri Mondor Hospital, Créteil, France

2. Addenbrooke’s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK

Abstract

Purpose: To evaluate the safety and success of target vessel cannulation in the visceral aortic segment using the Magellan robotic catheter system (RCS) during complex endovascular aortic procedures. Methods: Robotic navigation was attempted for access to 37 target vessels in 15 patients (14 men; mean age 75±10 years) during 16 fenestrated and/or branched stent-grafting procedures and 1 endovascular repair requiring the chimney technique. For each target vessel, robotic navigation was attempted for a maximum of 15 minutes; if cannulation was unsuccessful in that time, manual catheters were employed. Safety was evaluated by recording intraoperative adverse events, intraoperative complications related to robotic navigation, and postoperative complications. Technical success of robotic cannulation, wire cannulation times, and times for inserting the leader over the wire in the target vessels were recorded to assess RCS performance. Results: Successful robotic cannulation was achieved for 30 (81%) of the 37 target vessels, with a median wire cannulation time of 263 seconds (range 40–780) and a median 15 seconds (range 5–450) for inserting the leader over the wire. No intraoperative complications related to robotic navigation were observed. Seven of 27 arteries accessed via 7 fenestrations could not be cannulated within 15 minute s; all were cannulated successfully using conventional catheters (mean cannulation time 31±7 minutes). All 10 target vessels accessed via branches and chimney stents were successfully cannulated with the RCS. Conclusion: Cannulation of target vessels with the RCS during complex endovascular aortic procedures is feasible and safe. The robotic system was particularly effective for branched and chimney stents.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 31 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3