Candy-Plug Generation II for False Lumen Occlusion in Chronic Aortic Dissection: Feasibility and Early Results

Author:

Eleshra Ahmed1ORCID,Kölbel Tilo1ORCID,Tsilimparis Nikolaos1,Panuccio Giuseppe1ORCID,Scheerbaum Martin1,Debus E. Sebastian1,Mogensen John2,Rohlffs Fiona1ORCID

Affiliation:

1. German Aortic Center, Department of Vascular Medicine, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany

2. Cook Medical, Bjaeverskov, Denmark

Abstract

Purpose: To present the early results of false lumen (FL) occlusion in chronic aortic dissection using the Candy-Plug generation II (CP II), which has a self-closing fabric channel that obviates the need for separate occlusion of its center. Materials and Methods: Fourteen consecutive patients (mean age 60±11 years; 10 men) with persistent FL backflow and aneurysm formation at the thoracic segment in chronic aortic dissection underwent thoracic endovascular aortic repair (TEVAR) with FL occlusion using the refined CP II. Primary endpoints were technical success (successful deployment) and clinical success (no FL backflow at the CP II level). Secondary endpoints included 30-day mortality and morbidity and aortic remodeling during follow-up. Results: Technical success was 100%. One patient required additional intraprocedural FL embolization at the CP II level due to persistent FL backflow on final angiography (clinical success 93%), though there was no flow through the CP II center. There were no intraprocedural complications. Immediate complete FL occlusion was achieved in 12 patients; the other 2 required reintervention. One had contrast enhancement in the distal FL proximal to the CP II and was treated with coil embolization. The other patient had persistent type I endoleak at the level of the left subclavian artery (LSA) and underwent left carotid–LSA bypass and proximal stent-graft extension. One patient died due to retrograde type A aortic dissection that was not related to CP II placement. Over a mean 8-month follow-up (range 3–12), 9 patients had computed tomography angiography; 8 patients had evidence of aortic remodeling, while 1 aneurysm sac was stable. Conclusion: The CP II reduces the number of procedural steps and offers good seal, with minimal morbidity and mortality and a high rate of aortic remodeling.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 46 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3