A Percutaneous Approach to Deep Venous Valve Insufficiency with a New Self-Expanding Venous Frame Valve

Author:

de Borst Gerrit J.1,Teijink Joep A.W.2,Patterson Marlowe3,Quijano Tino C.3,Moll Frans L.1

Affiliation:

1. Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands

2. Department of Vascular Surgery, Atrium Medical Center, Heerlen, The Netherlands

3. Venpro Inc., Irvine, California, USA

Abstract

Purpose: To ascertain if a percutaneously delivered venous valve bioprosthesis (PVVB) can be implanted in the porcine venous system and function without complications. Methods: The PVVB is a glutaraldehyde-preserved, valve-bearing venous xenograft sutured inside a memory-coded nitinol frame (diameter 10, 12, or 14 mm). In 10 50-kg pigs, the external jugular vein was exposed, and a 16-F introducer sheath was positioned in the common iliac vein. One PVVB was inserted and deployed in each iliac vein under fluoroscopic control. After PVVB implantation, all animals were randomly given either vitamin K antagonists (1–2 mg/d) (group I) or a combination of aspirin (150 mg/d) and clopidogrel (75 mg/d) (group II), which were shown in a preliminary pilot study to be the most effective anticoagulation regimens in the pig model. Ascending and descending completion phlebograms were performed. PVVBs were evaluated with phlebography at 4 weeks to assess patency and competence; all PVVBs were explanted and processed for histological analysis. Results: In 8 animals, the PVVB was successfully deployed in both the left and right iliac veins. In 2 pigs, only 1 PVVB was inserted due to vascular anomalies. Completion phlebography demonstrated 18 patent and competent valves. At 2 weeks, bleeding complications occurred in 3 group I pigs; all 5 animals were terminated to prevent further complications. Of the 8 valves in this group, 7 were patent (3 competent) by phlebography; 1 PVVB had migrated due to known undersizing of the stent frame. At 4 weeks, group II (5 pigs, 10 valves) analysis revealed 5 patent (3 competent) valves; no bleeding complications occurred in this group. Histology showed thrombosis as the cause of occlusion in all 5 non-patent valves from group II. Conclusions: Deployment of a glutaraldehyde-fixed bovine vein sutured to a self-expanding nitinol stent in the porcine iliac vein is technically feasible. Development of a venous bioprosthesis that can be placed percutaneously may have important clinical applications as an endovascular treatment for chronic venous insufficiency when it is due to valvular incompetence.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3