Changes in Carotid Artery Flow Velocities after Stent Implantation: A Fluid Dynamics Study with Laser Doppler Anemometry

Author:

Greil Oliver,Pflugbeil Gottlieb,Weigand Klaus1,Weiß Wolfgang,Liepsch Dieter,Maurer Peter C.,Berger Hermann

Affiliation:

1. Laboratory for Fluid Mechanics, University of Applied Science, Munich, Germany

Abstract

Purpose: To study the influence of stent size and location on flow patterns in a physiological carotid model. Methods: Wallstents were positioned in silicon models of the carotid artery at various locations: 2 stents appropriately sized to the anatomy were placed in (1) the internal carotid artery (ICA) and (2) the ICA extending completely into the common carotid artery so as to cover the external carotid artery (ECA) orifice. Another 2 stents were placed in the ICA extending (1) partially and (2) completely into the bulb to simulate stent displacement and disproportion between stent size and the original vessel geometry. Measurements were performed with laser Doppler anemometry (LDA) using pulsatile flow conditions (Reynolds number=250; flow 0.431 L/min; ICA:ECA flow rate ratio 70:30) in hemodynamically relevant cross sections. The hemodynamic changes were analyzed with 1-dimensional flow profiles. Results: With the stent in the ICA, no changes of the normal flow profile were seen. For stents positioned in the ICA and extending partially or completely into the carotid bulb, the flow behavior was affected by the resistance of the stent to flow in the ECA. Hemodynamically relevant disturbances were seen in the ICA and ECA, especially in the separation zones (regions along the walls just after a bifurcation, bend, or curve). The ICA:ECA flow rate ratios shifted from 70:30 to 71.3:28.7 and from 70:30 to 75.1:24.9, respectively, in the 2 malpositioned stent models. With the stent placed in the ICA extending completely into the CCA, the ICA:ECA flow rate ratio shifted from 70:30 to 72.4:27.6. In this configuration, there were no notable flow changes in the ICA, but a clear diminishing of the separation zones in the ECA separation zones. Conclusions: Anatomically correct positioning of appropriately sized stents does not lead to relevant flow disturbances in the ICA. In the ECA, depending on the position, size, and interstices of the stent, the physiological flow was considerably disturbed when any part of the stent covered the inflow of the vessel. Disturbances were seen when the stent was positioned into the bulb. For clinical application, stent location and size must be carefully determined so that the stent covers the bifurcation completely or is in the ICA only.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3