Thirty-Day Results of the Novel CGuard-Covered Stent in Patients Undergoing Carotid Artery Stenting

Author:

Tigkiropoulos Konstantinos1ORCID,Papoutsis Ioakeim1ORCID,Abatzis-Papadopoulos Manolis1,Kousidis Panagiotis1ORCID,Mpismpos Dimitrios1,Melas Nikolaos1,Stavridis Kyriakos1,Karamanos Dimitrios1,Lazaridis Ioannis1,Saratzis Nikolaos1

Affiliation:

1. Vascular Unit, 1st University Surgical Department, Aristotle University, General Hospital Papageorgiou, Thessaloniki, Greece

Abstract

Objective: The aim of this study was to provide early-term evaluation, safety, and efficacy of the novel CGuard (Inspire MD, Tel Aviv, Israel) micromesh self-expanding stent with embolic protection system (EPS) during carotid artery stenting (CAS) procedure. Materials and Methods: All patients who underwent CAS with CGuard carotid stent system from January 2018 to September 2020 in a tertiary center were prospectively evaluated. Primary endpoints included technical success and perioperative neurological events (0–48 hours). Secondary endpoint was the rate of neurologic, cardiac events, and death (major adverse event or MAE) at 30 days. Patency of CGuard, peak systolic velocity (PSV), and end diastolic velocity (EDV) were evaluated at 30 days with duplex ultrasound. Results: A total of 103 patients underwent CAS procedure. Forty patients were symptomatic, and 63 patients were asymptomatic with stenosis greater than 70%. Technical success was 100%. Local anesthesia was applied in 94 patients (93%). Embolic protection devices were used in 6 patients (5.8%). Access site complications were 1.9%. Mean internal carotid artery stenosis diameter reduced from 79.47% to 14.68%. Two patients had transient ischemic attack (1.9%) and 1 patient experienced a cerebral hyperperfusion syndrome (CHS) perioperatively. External carotid artery (ECA) occlusion occurred in 1.9%. Four patients experienced jaw claudication (3.8%) postoperatively. Mean time of operation was 41 minutes. Mean duration of hospitalization was 3.1 days. The 30-day rate of MAE was 0%. CGuard patency was 100%, mean internal carotid PSV was reduced from 251.57 to 77.29 cm/s, and mean internal carotid EDV was reduced from 154.62 to 24.63 cm/s at 30 days. Conclusion: Our study shows that CGuard stent with EPS is an effective and safe device for treatment of carotid artery stenosis with acceptable low perioperative neurologic events, even with low embolic protection device usage. Larger multicenter and randomized studies are necessary to confirm its long-term efficacy.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司