Nonfluoroscopic 3D Image Guidance System Reduces Navigation Times Through Five 3D-Printed Iliofemoral Vascular Phantoms

Author:

Braga Daniel1ORCID,Ducaud Cristobal1,Camardo Andrew2,Hofacker Hannah2,Goel Vikash2ORCID,Beasley Robert3ORCID

Affiliation:

1. Department of Vascular and Interventional Radiology, Mount Sinai Medical Center, Miami, FL, USA

2. Centerline Biomedical, Inc., Cleveland, OH, USA

3. Palm Vascular Centers, Miami, FL, USA

Abstract

Purpose: To assess the potential adjunctive role of a 3D electromagnetic (EM) navigational system for use in above-knee vessels afflicted with peripheral artery disease (PAD). Peripheral artery disease can be challenging to operators encountering significant vessel tortuosity, calcium, and stenoses, which may require prolonged procedure times and excessive use of nephrotoxic iodinated contrast when performed with conventional fluoroscopy. Materials and Methods: Following appropriate ethical oversight, five 3D-printed bench phantoms modeling tortuous calcified PAD were created based on source CTA (computed tomography angiography) data sets from real patients. Investigational software was developed based on a commercially available aortic EM navigation platform (Intraoperative Positioning System [IOPS]; Centerline Biomedical, Inc., Cleveland, Ohio), with patient-specific structural maps of vessel lumens and calcification. Using a sensorized prototype 6 French (Fr) catheter and 0.035” guidewire, 15 interventionalists traversed each phantom using the EM platform as well as 2D simulated fluoroscopy-like image guidance and the times were recorded. Participants completed a 10-item standard system usability scale (SUS) questionnaire (score 1–5, 5= strongly agree) evaluating system usability and user satisfaction. Navigation times and SUS scores were compared with a 1-tailed statistical t test. Results: Participants demonstrated a statistically significant reduction in navigation times using EM guidance, performing 0.7 minutes (42 seconds) faster on average ( P < .001), corresponding to a 25% average relative reduction. Participants reported sufficiently high levels of usability satisfaction, with a mean SUS score of 4.29 ( P < .001), exceeding the acceptance criterion (score ≥3.5). Conclusion: This preclinical phantom study highlights the future potential of Centerline Biomedical’s EM navigation technology as a possible adjunct to fluoroscopy for highly precise visualization and navigation of PAD-afflicted vasculature. Clinical Impact This preclinical proof-of-concept study highlights the feasibility of EM navigation not only for branch vessel cannulation, but also for inline navigation of peripheral vessels afflicted with calcified plaques via benchtop iliofemoral phantom simulations. The navigation platform studied addresses the need for improvements in EM technology through modelling algorithms that facilitate 3D visualization of calcified plaque in any projection in real time, in addition to sensorization of both catheter and guidewire in a compact 6Fr system.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Endovascular repair of bilateral common iliac artery aneurysms using intraoperative positioning system;Journal of Vascular Surgery Cases, Innovations and Techniques;2024-10

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3