Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Vascular Closure Device During Percutaneous EVAR and TEVAR Procedures

Author:

Krajcer Zvonimir1ORCID,Wood David A.2,Strickman Neil1,Bernardo Nelson3,Metzger Chris4,Aziz Mark4,Bacharach J. Michael5,Nanjundappa Aravinda6,Campbell John6,Lee Jason T.7,Dake Michael D.7,Lumsden Alan8,Nardone Samuel9

Affiliation:

1. Texas Heart Institute and Baylor St Luke’s Hospital, Houston, TX, USA

2. Center for Cardiovascular Innovation, University of British Columbia, Vancouver, British Columbia, Canada

3. MedStar Health, Washington, DC, USA

4. Ballad CVA Heart Institution, Kingsport, TN, USA

5. Avera Heart Hospital, Sioux Falls, SD, USA

6. Charleston Area Medical Center, Charleston, WV, USA

7. Stanford University Medical Center, Palo Alto, CA, USA

8. The Houston Methodist Hospital, Houston, TX, USA

9. Teleflex Inc, Exton, PA, USA

Abstract

Purpose: To evaluate the safety and effectiveness of the MANTA percutaneous vascular closure device in patients undergoing percutaneous endovascular aneurysm repair (PEVAR) or thoracic endovascular aortic repair (TEVAR). Materials and Methods: The SAFE MANTA Study ( ClinicalTrials.gov identifier NCT02908880) was a prospective, single-arm, multicenter trial in patients undergoing endovascular interventions using large-bore sheaths (transcatheter aortic valve replacement, PEVAR, or TEVAR) at 20 sites in North America. Patient selection intended to test the MANTA device in populations without morbid obesity, severe calcification, or a severely scarred femoral access area. Of the 263 patients enrolled in the primary analysis cohort, 53 (20.2%) patients (mean age 74.9±8.9 years; 41 men) underwent PEVAR (n=51) or TEVAR (n=2) procedures and form the cohort for this subgroup analysis. Per protocol a single MANTA device was deployed in all PEVAR/TEVAR cases. Results: The mean time to hemostasis in the PEVAR/TEVAR cohort was 35±91 seconds, with a median time of 19 seconds vs 24 seconds in the overall SAFE MANTA population. The MANTA device met the definition for technical success in 52 (98%) of 53 PEVAR/TEVAR cases compared with 97.7% in the overall SAFE MANTA population. One (1.9%) major complication (access-site stenosis) occurred in this subgroup compared to 14 (5.3%) events in the SAFE population. In the PEVAR/TEVAR group, 1 pseudoaneurysm was noted prior to discharge, another at 30-day follow-up, and one at 60 days. One (1.9%) of the 3 minor pseudoaneurysms was treated with ultrasound-guided compression and the other 2 required no treatment. Conclusion: The MANTA device demonstrated a short time to hemostasis and low complication rates compared with published literature results of other percutaneous closure devices. Time to hemostasis and complication rates were comparable between the PEVAR/TEVAR patients and the full SAFE MANTA study cohort. The MANTA device provides reliable closure with a single percutaneous device for PEVAR/TEVAR procedures.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3