Aortic Arch Anatomy Pattern in Patients Treated Using Double Homemade Fenestrated Stent-Grafts for Total Endovascular Aortic Arch Repair

Author:

Chassin-Trubert Lucien1ORCID,Gandet Thomas1,Ozdemir Baris Ata1,Lounes Youcef1ORCID,Alric Pierre1,Canaud Ludovic1ORCID

Affiliation:

1. Department of Thoracic and Vascular Surgery, Arnaud de Villeneuve Hospital, Montpellier, France

Abstract

Purpose: To analyze the structural variation of the aortic arch and the supra-aortic arteries and establish an average spatial configuration that would be a pattern for a “universal double fenestration” design for physician-modified endovascular grafts (PMEGs) used in total thoracic endovascular aortic repair (TEVAR). Materials and Methods: Aortic arch morphology was retrospectively analyzed by reviewing the preoperative thoracic computed tomography angiography scans in 33 consecutive patients (mean age 68 years; 27 men) treated between January 2017 and March 2019 using double-fenestrated PMEGs for zone 0 TEVAR. Image analysis was completed according to a standardized technique on a vascular workstation with center lumen line reconstruction for all measurements. Variations in branching pattern of the aortic arch were classified into 8 types. Results: The arch trunk configuration was type I in 26 patients (79%), type II in 5 (15%), type III in 1, and type IV in 1. Mean aortic diameters at the level of mid ascending aorta, innominate artery (IA), left common carotid artery (LCCA), and left subclavian artery (LSA) were 35.7±3.7, 34.2±4.5, 33.3±6.7, and 33.7±4.7 mm, respectively. Mean diameters of the trunk were 12.2±1.7, 7.5±1.4, and 8.0±0.8 mm, respectively. Mean longitudinal center to center lengths were 15.9±2.5 mm between the LSA and LCCA and 12.1±3.0 mm between the LCCA and IA. Mean clock positions using the LSA as reference were 12:50 for the IA and 12:05 for the LCCA. In 32 patients (97%) all the supra-aortic branch vessels fit perfectly inside two delimited areas defined by a proximal common square area of 30×30 mm for the IA and LCCA and a second distal 8-mm-diameter circle for the LSA. Conclusion: Variations of the aortic arch anatomy are numerous and common. A general morphological pattern is described that delimits the aortic area where these variations occur. This information can be utilized for the design of an off-the-shelf double-fenestrated stent-graft for zone 0 TEVAR.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3