An Endovascular Model of Carotid Stenosis for the Evaluation of Thrombolysis and Angioplasty

Author:

Lin Peter H.1,Surowiec Scott M.1,Conklin Brian1,Bush Ruth L.1,Chen Changyi1,Chaikof Elliot L.1,Lumsden Alan B.1

Affiliation:

1. Division of Vascular Surgery, Emory University School of Medicine, Atlanta, Georgia, USA

Abstract

Purpose: To develop a porcine carotid artery thrombosis model using a novel stent-graft device to evaluate the efficacy of thrombolytic therapy and angioplasty procedures. Methods: An endovascular device made from a tapered polytetrafluoroethylene graft inverted in a self-expanding nitinol stent was delivered to bilateral carotid arteries via a right femoral approach in 16 pigs. Carotid thrombotic occlusion ensued from flow stasis created by the intrastent stenosis. Via selective carotid catheterization from a femoral approach, urokinase (250,000 IU) was pulse-sprayed in one carotid artery while a control saline solution was infused in the contralateral vessel; delivery times were 1 hour, 8 hours, 3 days, or 6 days after carotid occlusion (4 animals per time period). After thrombolysis, balloon angioplasty was performed to maintain carotid patency. Arteriography and intravascular ultrasound were used to evaluate the efficacy of thrombolysis. Light microscopy was used for histological analysis of the thrombus. Results: Carotid artery occlusion occurred in 15 ± 8 minutes after stent-graft placement in all animals. Urokinase was effective in recanalizing all occluded arteries in the 1-hour, 4-hour, and 3-day groups (100%) but was effective in only 2 of 4 animals in the 6-day group (p < 0.05). Overall thrombolytic efficacy was 78% ± 7%. Control saline solution showed no thrombolytic effect (p < 0.001). Angioplasty successfully restored normal luminal diameter in all fully lysed arteries (100%). Histological analysis showed fibrin-predominant thrombus with a varying degree of platelet deposition. Conclusions: This endovascular approach, which creates a carotid stenosis using this novel stent-graft device, is reliable in producing carotid thrombosis. In our model, thrombolytic therapy was effective in restoring luminal patency, and the intraluminal stenosis is amenable to balloon angioplasty. The model is useful for the evaluation of antithrombotic therapy and adjunctive endovascular interventions.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3