Technical Feasibility and Safety of a Snare-Less, EVAR–First Technique for Iliac Branch Endoprosthesis

Author:

Chen Julia Fayanne1ORCID,Loh Sarah Ann2,Fischer Uwe2,Nassiri Naiem234

Affiliation:

1. Division of Vascular and Endovascular Surgery, Department of Surgery, University of Toronto, Toronto, ON, Canada

2. Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale University School of Medicine, New Haven, CT, USA

3. Vascular & Endovascular Surgery, VA Connecticut Healthcare System, West Haven, CT, USA

4. Yale New Haven Hospital, Yale University School of Medicine, New Haven, CT, USA

Abstract

Objective: The purpose of this study was to evaluate the technical feasibility, safety, and early outcomes of a snare-less, endovascular abdominal aortic aneurysm repair (EVAR)-first technique (SET) for iliac branch endoprosthesis (IBE) placement. Methods: We retrospectively reviewed all patients who received IBEs between July 2018 and March 2022. Patients were divided into 2 categories based on method of IBE deployment: SET or Standard. Primary endpoints were technical success, major adverse events, mortality, reintervention, internal iliac artery (IIA) patency, and freedom from IIA branch instability. Technical success was defined by successful deployment of both the EVAR and the IBE with maintained patency of the IIA and no stent graft migration. Results: There were 20 patients (90% male, median age 72 [65.4-74.5] years) who underwent IBE placement. Among these, 5 (33.3%) underwent SET to treat 5 common iliac artery (CIA)/IIA aneurysms, while the remaining 15 (66.7%) underwent standard IBE deployment with through-and-through femoral access (n=13) or trans-brachial access (n=2) to treat 19 CIA/IIA aneurysms. Overall median renal to iliac bifurcation length was 169 (152-177) mm, with 9 patients falling short of the minimum of 165 mm for on-label IBE placement. Median contrast used was 148 (120-201) mL, fluoroscopy time 42.8 (35.0-49.8) minutes, estimated blood loss 200 (100-275) mL, and procedure time 192 (167-246) minutes, with no significant differences between the 2 groups. Technical success was achieved in 100% of cases. At 30 days, there were no mortalities or major adverse events in either group; there were 100% IIA patency, no IIA instability, and no reinterventions in both groups. Median follow-up in the SET group was 5.7 (5.5-6.2) months, with 1 death at 6 months and 1 type 1B endoleak at 6 months requiring reintervention. Median follow-up for the Standard group was 1.6 (0.8-2.1) years with 2 non–aneurysm-related deaths and no reinterventions at 1 year. Conclusions: SET for IBE is a safe and effective approach that decreases technical complexity and mitigates anatomic barriers to IBE placement. Clinical Impact SET for IBE is a safe and effective approach to IBE placement that decreases technical complexity. A critical component to this technique is a large bore sheath with a stiff steerable tip. Importantly, this approach also mitigates anatomic barriers to IBE placement, expanding applicability of IBE technology to patients who may be otherwise ineligible.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3