Outcomes of Percutaneous Access to the First Versus Third Segment of Axillary Artery During Aortic Procedures

Author:

Melloni Andrea1ORCID,Bertoglio Luca1ORCID,Van den Eynde Wouter2,Agrusa Christopher J.3,Parlani Gianbattista4,Howard Dominic P. J.5,Rio Javier6ORCID,Fazzini Stefano7,Mansour Wassim8ORCID,Dias Nuno V.9ORCID,Ronchey Sonia10ORCID,Branzan Daniela11ORCID,Luo Xun,Chu Rosa Aurora,Di Marzo Luca,Ippoliti Arnaldo,Simonte Gioele,Ligero Jose M.,Locca Maria Lucia,Scheinert Dierk,Schmidt Andrej,Sonesson Björn,Verbist Jürgen,Chiesa Roberto

Affiliation:

1. Division of Vascular Surgery, Vita-Salute San Raffaele University, IRCCS San Raffaele Scientific Institute, Milan, Italy

2. Department of Vascular and Thoracic Surgery, Imelda Hospital, Bonheiden, Belgium

3. Division of Vascular Surgery, New York-Presbyterian Hospital/Weill Cornell Medical Center, New York, NY, USA

4. Vascular and Endovascular Surgery Unit, S. Maria Misericordia Hospital, University of Perugia, Perugia, Italy

5. Department of Vascular Surgery, Oxford University Hospitals NHS Trust, Oxford, UK

6. Servicio de Angiología y Cirugía Vascular, Hospital General Universitario Gregorio Marañón, Madrid, Spain

7. Vascular Surgery Unit, Biomedicine and Prevention Department, University of Rome Tor Vergata, Rome, Italy

8. Vascular and Endovascular Surgery Division, Department of Surgery “Paride Stefanini,” Policlinico Umberto I, “Sapienza” University, Rome, Italy

9. Department of Thoracic Surgery and Vascular Diseases, Vascular Centre, Skåne University Hospital, Malmö, Sweden

10. Department of Vascular Surgery, San Filippo Neri Hospital, Rome, Italy

11. Department of Vascular Surgery, University Hospital Leipzig, and Helmholtz Institute for Metabolic, Obesity and Vascular Research (HI-MAG) of the Helmholtz Zentrum Munich at the University of Leipzig and University Hospital Leipzig, Leipzig, Germany

Abstract

Purpose: This article aims at investigating the outcomes of percutaneous access via the first versus third axillary artery (AXA) segments with closure devices during aortic procedures. Materials and Methods: All patients receiving percutaneous AXA access closed with Perclose ProGlide device (Abbott, Santa Clara, California) from 2008 to 2021 were included in a retrospective multicenter registry (NCT: 04589962). Efficacy endpoint was the technically successful percutaneous procedure (no open conversion). Safety endpoints were stroke and access complications according to the Valve Academic Research Consortium-3 reporting standards. The first (AXA1) or third (AXA3) axillary puncture sites were compared. Results: A total of 412 percutaneous AXA accesses were included: 172 (42%) in AXA1 and 240 (58%) in AXA3. Left AXA was catheterized in 363 cases (76% of AXA1 vs 97% of AXA3, p<0.001) and 91% of fenestrated/branched endovascular repair (F/BEVAR) procedures were conducted from the left. A ≥12F internal diameter (ID) sheath was used in 49% of procedures. Open conversion rate was 1%, no major vascular complications occurred, and only one major non-vascular complication was recorded. Primary closure failure occurred in 18 AXA1 (11%) and 32 AXA3 accesses (13%), treated by covered (8.3%) or bare-metal (2.7%) stenting. Bailout stent patency was 100% at median follow-up of 12 months, with 6 of 6 stents still patent after >36 months of follow-up. Stroke rate was 4.4%. An introducer sheath >12F was independently associated with both access complications (p<0.001) and stroke (p=0.005), while a right-side access was associated with stroke only (p=0.034). Even after adjustment for covariates, AXA1 versus AXA3 showed an equal success rate (odds ratio [OR]=0.537, 95% confidence interval [CI]=0.011–1.22 for AXA3, p=0.104). The combination of AXA3 and a >10F introducer sheath provided worse outcomes compared with >10F sheaths through AXA1 (OR for success=0.367, 95% CI=0.176–0.767, p=0.008). This was not confirmed for >12F sheaths, associated with similar outcomes (p=0.31 AXA 1 vs AXA 3). Conclusion: Major local complications with the percutaneous axillary approach and ≤12F sheaths are infrequent and solvable by complementary endovascular interventions. Stroke risk remains an issue. First and third AXA segments are both amenable for access with good results, but larger sheaths (12F) perform better in AXA1. Clinical Impact Percutaneous access with vascular closure devices at the first or third axillary artery (AXA) segments during aortic procedures is burdened by a negligible risk of open conversion. Local complications with the percutaneous axillary approach are infrequent and solvable by complementary endovascular interventions. First and third AXA segments are both amenable to access with excellent results, but larger sheaths (12F) perform better in the wider first AXA segment. In this setting, bailout stenting does not appear to be associated with mid-term stent occlusion.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3