Guideline Compliance and Indications for Inferior Vena Cava Filter Placement at a Quaternary Care Medical Center

Author:

Choe June1ORCID,Liang Richard12,Weinberg Aaron S.1,Tapson Victor F.1

Affiliation:

1. Division of Pulmonary and Critical Care Medicine, Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA

2. School of Medicine, Stanford University, Stanford, CA, USA

Abstract

Purpose: This study investigated physician compliance with indications for inferior vena cava (IVC) filter placement according to the 2012 American College of Chest Physicians (ACCP) and the 2011 Society of Interventional Radiology (SIR) guidelines. Materials and Methods: A retrospective medical record review of 231 retrievable IVC filters placed between August 15, 2016, and December 28, 2017, at a large urban academic medical center. Guideline compliance to the 2012 ACCP and the 2011 SIR guidelines, and indications for IVC filter placements were assessed through an adjudication protocol. Filter retrieval and complication rates were also examined. Results: Compliance to guidelines was low (60.2% for ACCP; 74.0% for SIR), especially for non-intensive care unit (ICU) patients (ICU 74.6% vs non-ICU 54.8%, p=0.007 for ACCP; ICU 82.5% vs non-ICU 70.8%, p=0.092 for SIR). After adjudication, 8.2% (19/231) of filters were considered non-indicated but reasonable, 17.7% (41/231) non-indicated and unreasonable, and 13.9% (32/231) SIR-indicated but not ACCP-indicated. The most common indication was venous thromboembolism with contraindication to anticoagulation. The most common reasons for non-compliance were distal deep venous thrombosis with contraindication to anticoagulation (19/60, 31.6%) and clot burden (19/60, 31.6%). One-year filter retrieval and 90-day complication rates were 32.0% (74/231) and 6.1% (14/231), respectively. Conclusion: Compliance to established guidelines was low. Reasons for non-compliance included limitations or discrepancies in guidelines, as well as non–evidence-based filter placements. Clinical Impact Despite increasing utilization of inferior vena cava (IVC) filters, guideline compliance for IVC filter placement among providers is unclear. The results of this study indicate that physician compliance to established guidelines is poor, especially in non-intensive-care-unit patients. Noncompliance stems from non-evidence-based filter placement as well as differences and limitations in guidelines. Avoiding non-indicated IVC filter placement and consolidation of guidelines may significantly improve guideline compliance. The critical insights gained from this study can help promote judicious use of IVC filters and highlight the role of venous thromboembolism experts in navigating complex cases and nuances of guidelines.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Rückholbare Vena-cava-Filter: Leitlinienempfehlungen finden geringe Beachtung;Gefäßmedizin Scan - Zeitschrift für Angiologie, Gefäßchirurgie, diagnostische und interventionelle Radiologie;2024-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3