Inferior Vena Cava—Balloon Occlusion and Its Effect on the Myocardium During Endograft Deployment in the Arch

Author:

Karelis Angelos1ORCID,Dias Nuno V.1ORCID,Holmström Anders2,Kölbel Tilo3ORCID,Sonesson Björn1ORCID

Affiliation:

1. Department of Thoracic Surgery and Vascular Diseases, Vascular Center, Skåne University Hospital, Malmö, Sweden

2. Department of Intensive and Perioperative Care, Skåne University Hospital, Malmö, Sweden

3. Department of Vascular Medicine, German Aortic Centre Hamburg, Hamburg, Germany

Abstract

Purpose: To evaluate the impact of cava balloon occlusion on the myocardium during endovascular repair of thoracic aortic pathologies. Material and methods: A prospective observational cohort study of 21 patients who underwent endovascular repair of aortic arch and thoracic aorta in a single tertiary referral center with use of inferior vena cava (IVC) balloon occlusion as a method of intraoperative cardiac output reduction. Pre-, intra-, and postoperative measurements of heart rate, blood pressure, stroke volume index, and central venous oxygen saturation were noted. High-sensitive serum troponin levels were also analyzed according to a pre-established protocol. Endpoints were cardiac troponin T levels after induced hypotension and left ventricular ejection fraction during follow-up. Secondary endpoints were procedure technical success and overall survival. Results: Twenty-one patients (18 male, median age 69, (62-75, IQR)) enrolled in the study between May 2015 and January 2019. Indication for endovascular treatment was an aortic arch aneurysm (n=10), descending aortic aneurysm (n=8), lusorian artery aneurysm (n=2), and thoracoabdominal aortic aneurysm (n=1). Median time to reach half mean arterial pressure was 60 seconds while median recovery time of blood pressure was 135 seconds. In 5 (24%) cases, we observed a > 50% change of Troponin T on the reference level. Technical success was achieved in all cases. Two (10%) patients developed new and persistent atrial fibrillation and 1 (5%) suffered a peri-operative ST-elevation myocardial infarction. Conclusion: The use of IVC balloon occlusion is a feasible technique for cardiac output reduction during endovascular repair of thoracic aortic pathologies. One fourth of the patients develop significant troponin leakage but the significance of the finding needs further studies.

Funder

Hulda Almroth Foundation

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3