Intravascular Ultrasound in Branched and Fenestrated Endovascular Aneurysm Repair: Initial Experience in a Single-Center Cohort Study

Author:

Gennai Stefano1,Leone Nicola1ORCID,Saitta Giuseppe1,Migliari Mattia1,Lauricella Antonio1,Farchioni Luca1,Silingardi Roberto1

Affiliation:

1. Department of Vascular Surgery, Ospedale Civile di Baggiovara, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio Emilia, Modena, Italy

Abstract

Purpose: To evaluate intravascular ultrasound (IVUS) safety and efficacy to detect visceral stenting issues during complex endovascular aneurysm repair through branched and fenestrated repair (B-FEVAR). Materials and Methods: A single-center retrospective analysis of 33 bridging stents assessed intraoperatively using IVUS between January and September 2020 was performed. Ten aortic aneurysm patients [7 thoracoabdominal / 1 pararenal / 2 juxtarenal; 3 females; mean age 73 years [range 70–77 years]) were included. Eight BEVAR (5 standard; 2 custom-made) and 2 FEVAR (custom-made) were performed. The study assessed the safety and efficacy of IVUS utilization to detect immediate branch instability after visceral stenting in the case of B-FEVAR. The primary safety endpoint was defined as the absence of IVUS-related adverse events. The primary efficacy endpoint was defined as the composite of technical success of the IVUS-assessment in each target visceral vessels (TVVs), the rate of IVUS-findings divided as prompting additional maneuvers or not, and the incidence of postoperative computed tomography angiography findings compared with intraoperative assessment. Results: There were no IVUS-related adverse events. The technical success of the IVUS-assessment was achieved in all TVVs. No technical issues compromised the evaluation of the intended vessel. Among the 7 findings identified by IVUS, 3 were suspected at the angiography. In all, 57% (4/7) had normal final angiography. IVUS was able to detect a 12% (4/33) intraoperative branch instability not identified/suspected at the completion angiography. The IVUS assessment led to an immediate revision in 5 (15%) vessels. A total of 57% (4/7) of the issues were detected in patients undergoing primary BEVAR. The remaining 43% (3/7) was detected in patients undergoing secondary intervention for branch instability. Conclusion: IVUS was safe as an adjunctive imaging technique to assess completion after B-FEVAR. It demonstrated efficacy in the detection of intraoperative issues missed by angiography. Further investigations are required to validate these promising results.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3