Affiliation:
1. Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant’Orsola-Malpighi Hospital, Bologna, Italy
Abstract
Introduction: The aim of the study is to report a single-center experience with the Gore Excluder conformable endograft with active control system (CEXC Device, W.L. Gore and Associates, Flagstaff, AZ, USA) in abdominal aortic aneurysms (AAAs) with severe infrarenal neck angulation. Methods: All patients underwent EVAR with CEXC Device between September 2018 and 2020, were prospectively enrolled, and retrospectively analyzed. Anatomical details of the proximal aortic neck were evaluated. Early endpoints were the use of repositionability and angulation system, intraoperative unplanned cuff, technical success (TS), 30-day morbidity/mortality, and reintervention. Follow-up endpoints were type-I endoleaks, endograft migration, aortic neck dilatation, aneurismal sac shrinkage, survival (S), and freedom from reintervention (FFR). Results: Twenty-five patients were enrolled (median age: 80 [range = 60-90] years, median AAA diameter: 60 [range = 52-90] mm). All patients had severe infrarenal neck angulation (beta angle ≧ 60°), and 11 (44%) of those had neck beta angle ≧ 90°. Median infrarenal neck angle, length, and diameter were 70° (range = 60°-90°), 22 (range = 13-42) mm and 22 (range = 18-31) mm, respectively. Endograft repositioning system was employed in 15 (60%) cases and the median number of repositioning maneuvers was 1 (range:0-4). Active angulation system was used in 17 (68%) patients. The median proximal diameter of the main-body and oversize were 28 (range = 23-36) mm and 28% (range = 21%-38%), respectively. Proximal cuff was positioned in 1 (4%) patient. Technical success was achieved in all cases. Intraoperative and perioperative morbidity and mortality were 12% and 0%, respectively. Perioperative type-I/III and II endoleaks were observed in 0 and 4 (16%) patients, respectively. The median follow-up was 12 months (range: 3-30). One patient died at 12-month for AAA-unrelated causes. Abdominal aortic aneurysm-sac shrinkage and stability were observed in 9 (36%) and 15 (60%) cases, respectively. No type-I/III endoleak and reintervention occurred during the follow-up. One persistent type-II endoleak was observed. Estimated survival at 24 months was 92%. Conclusion: According to the present data, the CEXC Device allows an excellent rate of TS in severe angulated aortic neck. This preliminary data, could increase the rate of patients eligible for EVAR.
Subject
Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献