Clinical Utility of Intravascular Ultrasound (IVUS) in Carotid Artery Interventions: A Systematic Review and Meta-analysis

Author:

Mishra B.1,Pandit A. K.1ORCID,Miyachi S.2,Ohshima T.2ORCID,Kawaguchi R.2,Vishnu V. Y.1,Misra S.1,Srivastava M. V. P.1,Srivastava A. K.1,Kale S. S.3,Phalak M.3

Affiliation:

1. Department of Neurology, All India Institute of Medical Sciences, New Delhi, India

2. Department of Neurological Surgery, Neuroendovascular Therapy Center, Aichi Medical University, Nagakute, Japan

3. Department of Neurosurgery, All India Institute of Medical Sciences, New Delhi, India

Abstract

Background: Carotid plaque morphology plays an important role in determining outcome of carotid artery stenting (CAS). Intravascular ultrasound (IVUS) and its extension VH (Virtual Histology)-IVUS evaluate plaque characteristics in real time and guide decision making during stenting. To date, there is no consensus about indications of IVUS and its validated methods. This systematic review and meta-analysis aims to evaluate the clinical utility of IVUS in carotid artery interventions (CAS) and develop a future consensus for research and practice parameters. Methods: A systematic review and meta-analysis was performed of the English literature articles published till February 2021. Studies reporting on IVUS parameters and findings and also its performance compared with other imaging modalities were included in review. Pooled prevalence with 95% confidence intervals (CI) was calculated. The statistical analysis was conducted in R version 3.6.2. Results: A total of 2015 patients from 29 studies were included. Proportional meta-analysis was performed on 1566 patients from 11 studies. In 9 studies, stroke/transient ischemic attack (TIA) had a pooled prevalence of 4% (95% CI 3%–5%) while asymptomatic stroke had a pooled prevalence of 46% (95% CI 31%–62%) in 4 studies following IVUS. Two studies reported that IVUS detected more plaque protrusion compared with angiography (n=33/396 vs 11/396). IVUS led to stent type or size change in 8 of 48 cases which were missed on angiography in 3 other studies. Concordance between VH-IVUS and true histology was good at 80% to 85% reported in 2 studies. Conclusions: This systematic review and meta-analysis showed, though IVUS fared better to computed tomography (CT)/magnetic resonance (MR) angiography for better stent selection during CAS, with low to moderate risk of bias in the studies included. However, large scale, preferably randomized controlled studies are needed to predict its role in determining clinical outcome.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Reference48 articles.

1. Intravascular ultrasound—an overview. ScienceDirect. https://www.sciencedirect.com/topics/neuroscience/intravascular-ultrasound. Accessed July 5, 2021.

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3