Type 2 Endoleak Detection After Endovascular Aneurysm Repair: Can Low-Flow Endoleaks Also Be Visualized in Silicon-Photomultiplier-Based Positron Emission Tomography/Computed Tomography Scans?

Author:

Harigai Ayaka1ORCID,Toyama Yoshitaka1ORCID,Umetsu Michihisa2ORCID,Takanami Kentaro1,Takase Kei1

Affiliation:

1. Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan

2. Division of Vascular Surgery, Department of Surgery, Tohoku University Hospital, Sendai, Japan

Abstract

Purpose: To present a novel clinical application of silicon-photomultiplier-based positron emission tomography (SiPM-based PET)/computed tomography (CT), detecting a type II endoleak 5 years after endovascular aneurysm repair (EVAR). Technique: SiPM-based PET/CT scans with a standard whole-body protocol were performed for a 73-year-old man with a past medical history of abdominal aortic aneurysms treated with EVAR and currently under investigation of his duodenal papillary carcinoma. The PET/CT demonstrated 18F-fluorodeoxyglucose (FDG) accumulation outside the stent graft in the native sac of the aneurysm. The site of accumulation corresponded to that of the contrast enhancement depicted in the CT angiography taken 1 month earlier. Another CT scan performed 3 months later revealed enlargement of the aneurysm. Conclusion: SiPM-based PET/CT, with its superior sensitivity and spatial resolution over conventional PET/CT, can detect type II low-flow endoleaks. Clinical Impact Abnormal intra-aneurysmal FDG activity incidentally detected on SiPM-based PET/CT is worthy of attention because it may be indicative of endoleaks. Additional imaging using different modalities should be considered so that the patient would not miss the additional treatment opportunity upon observing sac enlargement. For patients with contraindications for iodine CT contrast media, SiPM-based PET/CT would serve as a suitable alternative.

Funder

Japan Society for the Promotion of Science

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3