Distribution of Sac Pressure in an Experimental Aneurysm Model after Endovascular Repair: The Effect of Endoleak Types I and II

Author:

Xenos Eleftherios S.1,Stevens Scott L.1,Freeman Michael B.1,Pacanowski John P.1,Cassada David C.1,Goldman Mitchell H.1

Affiliation:

1. Division of Vascular Surgery, University of Tennessee Medical Center, Knoxville, Tennessee, USA

Abstract

Purpose: To study in an experimental aneurysm model the differential distribution of strain/pressure (S/P) on the aneurysm wall before and after endograft exclusion and in the presence of individual type I and type II endoleaks. Methods: Two tapered elliptical Gore-Tex patches were sutured to an anterior and posterior longitudinal arteriotomy of an 8-mm Gore-Tex tube graft, thus creating a fusiform aneurysm. Two S/P transducers were placed at the proximal sac adjacent to the proximal neck, 2 at the site of the widest sac diameter, and 2 at the sac adjacent to the distal neck. The aneurysm, which was connected to a pulsatile pump system, was excluded using a 10-mm endograft. Type I and type II endoleaks were created and tested individually. S/P measurements were obtained at systemic systolic pressures (BP) of 80, 110, and 150 mmHg. Thrombosis of the sac contents was induced by injection of thrombin and calcium in the sac. Angiography was used to verify presence or absence of flow in the sac. Results: Aneurysm exclusion resulted in significant S/P reductions at all 3 BP levels versus prior to exclusion (p<0.05). Thrombus in the sac did not alter S/P in the excluded sac (p>0.05 for all 3 BP levels). In the presence of a proximal type I endoleak, S/P distribution was not uniform, and S/P at the proximal neck was close to S/P prior to exclusion (p>0.05 no graft versus type I endoleak for all 3 BP levels). This was also true in the presence of thrombus. With a type II endoleak, S/P was more evenly distributed and was not significantly elevated compared to the pressure without an endoleak (p>0.05, graft versus type II endoleak for all 3 BP levels). Thrombus had no effect on intrasac S/P with a type II endoleak. Intrasac S/P was significantly higher in the presence of a type I endoleak compared to a type II endoleak when BP=150 mmHg (p=0.008). Conclusions: Endovascular exclusion of an aneurysm results in uniform S/P reduction in the aneurysm sac. Type I endoleak, but not type II endoleak, results in significantly higher S/P in an area of the sac adjacent to the proximal neck. Thrombus does not result in significantly different S/P distribution in the aneurysm sac.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3