Abstract
Aim: We present a case of successful endovascular repair of late ruptured aortic anastomotic pseudoaneurysm following previous left subclavian artery–descending thoracic aorta bypass and concomitant emergency thoracic endovascular aortic repair (TEVAR) of complicated endovascular aortic de-coarctation never previously described is also presented. A review of the intraoperative, 30-day, and follow-up morbidity, mortality, and complications of TEVAR as endovascular treatment of late aneurysm/pseudoaneurysms after surgical aortic de-coarctation was also performed. Methods: The systematic review was performed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement and following PICO model. A literature search was conducted on MEDLINE, PubMed, EMBASE, Cochrane Library, Google Scholar, Science Direct, and Web of Science using the words “tevar of late complication of aortic coarctation surgical repair” and “endovascular repair of anastomotic pseudoaneurysm in coarctation” up to June 17, 2022. Data were extracted from study documents about study design, patient’s demographics and comorbidities, details about primary surgical repair, type of late complication, time between open surgery and occurrence of complications, details of the secondary endovascular procedure with technical success, early, and follow-up mortality and morbidity. Results: A total of 18 papers were included with 78 patients (48 men, 69.5%). The most frequent type of primary open surgical repair was patch aortoplasty (46, 58.9%). Focusing on aneurysm and pseudoaneurysm as late complications, most of the patients were asymptomatic (45, 57.7%). All patients underwent TEVAR, 14 of them (17.9%) in urgent/emergent setting. The technical success was 98.7%, with 1 intraoperative death due to rupture of the aorta. In total, 31 patients out of 78 (39.7%) showed different complications in the immediate postoperative time, with type II endoleak being the most observed (8/31, 25.8%). The mean follow-up time was about 2 years (26.5 months, range 3–92). Overall, 30-day mortality was 2.6%. Complications occurred in 30 patients (39.4%), 23 of them resolved during the follow-up period. Conclusions: With the limit of low-quality data, TEVAR can be considered a safe and effective option for the treatment of late complications after open surgery for aortic coarctation, even in urgent settings. Clinical Impact Different specialists have to face the technical complexities and risks related to treatment of late complications after surgical de-coartaction, which can be either surgical or endovascular, and depend on patient’s ages. Although covered stents appear to have some protection from the development of stent fractures, doesn’t provide complete protection from late aneurysm formation. In this setting, TEVAR may represent a valuable option, combining the advantages of the covered stent with those of a device that can cover a wider range of aortic length, especially in adult patients. This study shows thoracic endovascular repair can be considered a safe and effective option in clincal practice for the treatment of late complications after open surgery for AC, even in urgent settings.
Subject
Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery