Analysis of Risk Factors for Early Type I Endoleaks After Thoracic Endovascular Aneurysm Repair

Author:

Kanaoka Yuji1,Ohki Takao1,Maeda Koji1,Baba Takeshi1

Affiliation:

1. Division of Vascular Surgery, Department of Surgery, Jikei University School of Medicine, Tokyo, Japan

Abstract

Purpose: To evaluate risk factors for early (<30 days) type I endoleak following thoracic endovascular aortic repair (TEVAR). Methods: A retrospective study was conducted of 439 consecutive patients (mean age 74.0±10.0 years; 333 men) who underwent TEVAR at a single center between June 2006 and June 2013. Pathologies included 237 aortic arch aneurysms and 202 descending thoracic aortic aneurysms (dTAA). Maximum TAA diameter was 63.6±13.7 mm. Among the distal aortic arch aneurysms, 124 required coverage of the left subclavian artery (LSA), while the remaining 113 arch aneurysms had debranching (n=40), the chimney technique (n=52), and a branched stent-graft (n=13). Eight patients with dilatation of the ascending aorta underwent arch replacement with elephant trunk prior to TEVAR. Predictive factors for type I endoleak were explored in univariate analysis and examined for each outcome using logistic regression models; results are given as the odds ratio (OR) and 95% confidence interval (CI). Results: Among 439 TEVAR cases, 37 (8.4%) had type I endoleaks on imaging at 1 month; 31 were in the 237 arch cases (13.1%). Endoleak investigation by site indicated a low incidence (3.0%) for dTAAs and markedly low (1.4%) in zone 4. Significantly more endoleaks were observed in zones 0–2 than in zone 4 (p<0.001). On univariate analysis, significant associations were found between endoleak and LSA coverage (OR 5.8, 95% CI 2.4 to 14.4, p<0.001), operative time ≥240 minutes (OR 3.7, 95% CI 1.5 to 6.2, p=0.002), and ≥270 mL of contrast (OR 2.8, 95% CI 1.4 to 5.8, p=0.004). Among the aortic branch reconstruction procedures, the chimney technique was the only maneuver associated with a significant risk of endoleak (OR 5.3, 95% CI 2.3 to 11.2, p<0.001). Arch state was not correlated with endoleaks, but ≥38-mm proximal neck diameter (OR 3.6, 95% CI 1.2 to 10.8, p=0.023), stent-graft diameter ≥40 mm (OR 9.9, 95% CI 1.4 to 30.5, p=0.015), and excessively oversized (≥14%) stent-grafts (OR 3.5, 95% CI 1.2 to 10.3, p=0.020) were; the proximal neck length was not correlated with endoleaks if a proximal neck length >10 mm can be secured. Conclusion: Risks for early type I endoleaks after TEVAR for aneurysm were landing zone 0–2, LSA coverage, large proximal neck and stent-graft diameters, excessive oversizing, and the use of the chimney technique.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3