Objective Evaluation With Noncontrast Computed Tomography Can Reveal Calcified Plaque Solidity in Peripheral Artery Diseases

Author:

Ozaki Dai1ORCID,Yokoyama Ken1,Miyazaki Tetsuro1,Hirabayashi Koji1,Abe Hiroshi1,Yabe Kosuke1,Kakihara Midori1,Maki Masaaki1,Shimai Ryosuke1,Isogai Hiroyuki1,Ouchi Shohei2,Yasuda Yuki1,Odagiri Fuminori1,Takamura Kazuhisa1,Yaginuma Kenji1,Tokano Takashi1,Iwasaki Takashi3,Kawai Satoru3,Minamino Toru2ORCID

Affiliation:

1. Department of Cardiology, Juntendo University Urayasu Hospital, Urayasu-shi, Japan

2. Department of Cardiovascular Biology and Medicine, Juntendo University Hospital, Tokyo, Japan

3. Department of Radiology, Juntendo University Urayasu Hospital, Urayasu-shi, Japan

Abstract

Purpose: The presence of severely calcified plaque remains problematic in endovascular therapy, and no specific endovascular treatment strategy has been established. Estimating plaque solidity before the procedure may help operators penetrate calcified plaque with a guide wire. The aim of this study was to establish a method of measuring plaque solidity with noncontrast computed tomography (CT). Methods: This retrospective, single-center study included consecutive patients who, between October 2020 and July 2022, underwent noncontrast 5 mm and 1 mm CTs before endovascular therapy to penetrate calcified plaque with a wire in the common femoral, superficial femoral, and popliteal arteries. Three cross-sectional CT slices were selected. To target a calcified plaque lesion, the operator identified a region of interest, which corresponded to 24×24 pixels, and Hounsfield unit (HU) values of each pixel were displayed on the CT image. The average HU values and the ratio of number of pixels of lower values (130–599 HU) represented plaque solidity. We used the Mann-Whitney-Wilcoxon rank-sum test and the chi-square test to compare the solidity of plaques penetrated and not penetrated by the wire. Results: We evaluated 108 images of 36 calcified plaque lesions (in 19 patients). The wire penetrated 28 lesions (77.8%) successfully. The average HU value was significantly lower in the lesions that the wire penetrated than in the others, in both the 5 mm CT slices (434.7±86.8 HU vs 554.3±112.7 HU, p=0.0174) and 1 mm slices (497.8±103.1 HU vs 593.5±114.5 HU, p=0.0381). The receiver operating curve revealed that 529.9 and 533.9 HU in the 5 and 1 mm slices, respectively, were the highest values at which wires could penetrate. Moreover, at the lesions that were penetrates successfully, the ratio of number of lower HU value pixels was significantly higher both in 5 mm slice CTs (74.7±13.4 vs 61.7±13.1%, p=0.0347) and 1 mm (68.7±11.8 vs 57.1±11.4%, p=0.0174). Conclusion: The use of noncontrast CT to evaluate plaque solidity was associated with successful wire penetration of calcified lesions in peripheral arteries. Clinical Impact This study revealed an association between the wire penetration inside calcified plaque and plaque solidity estimated using non-contrasted computed tomography. The mean Hounsfield unit values of three cross-sections in calcified plaques were associated with the successful wire penetration. This wire penetration difficulty is associated with extended procedure time, excessive radiation exposure, usage of extra contrast agents, and increased medical costs. Therefore, estimating calcified plaque solidity before procedure enables us to choose effective and lean procedures. In addition, to predict the success of dilating calcified plaque from the inside is also beneficial when the operator wants to avoid extra scaffold implantation for target lesions.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Reference16 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3