Bare Stent Fracture After TEVAR With the Modified Restrictive Bare Stent (RBS) Technique in Type B Aortic Dissections

Author:

Lescan Mario1ORCID,Andic Mateja1,Bonorden Constantin1ORCID,Schano Julia1,Hahn Julia1,Schlensak Christian1,Mustafi Migdat1

Affiliation:

1. Department of Thoracic and Cardiovascular Surgery, University Medical Center Tübingen, Tübingen, Germany

Abstract

Purpose: The aim was to assess the mid-term aortic remodeling and bare-metal stent (BMS) integrity of the restricted bare stent (RBS) technique reconstruction in aortic dissections. Materials and Methods: This retrospective cohort study included prospectively collected patients treated with the modified RBS technique between 2017 and 2020. The preoperative, postoperative, and last follow-up computed tomographic (CT) scans were analyzed in the centerline at the mid-descending, celiac trunk (CeT), and the mid-abdominal levels for false lumen (FL) patency, aortic diameter, and true lumen (TL) diameter changes. Bare-metal stent integrity was assessed in the 3-dimensional multiplanar reformats. Results: The median follow-up of the cohort (n=17) was 26 (11, 45) months. The procedure was mainly performed with the Relay NBS endograft (15/17; 88%) + E-XL BMS (17/17; 100%). Postoperative mortality, paraplegia, stroke, renovisceral vessel loss, and type I and III endoleaks were not observed. BMS fractured in 6 patients (6/17; 36%), damaged the dissection flap in 4/17 (24%), and led to the reperfusion of the FL and re-interventions with TEVAR (4/17; 24%). Two patients without FL reperfusion showed stable CT follow-ups 13 and 17 months after the fracture diagnosis. The TL expansion was seen at all landmarks and peaked in the thoracic aorta (+10; 6, 15; p<0.001). The FL thrombosis after modified RBS was only relevant in the thoracic aorta (p<0.001) and at CeT (p=0.003). The aortic diameter was stable in the thoracic aorta and increased at distal landmarks (CeT [+5; 1, 10; p=0.001]; mid-abdominal [+3; 1, 5; p=0.004]). Conclusion: The modified RBS technique could not stop aortic growth below the diaphragm and prevent new membrane rupture due to the fractures of the BMS and consecutive flap damage with the reperfusion of the FL. Clinical Impact The treatment of complicated type B aortic dissections with TEVAR has become a standard. Particularly, patients with true lumen collapse and malperfusion may benefit from a more aggressive treatment strategy including proximal TEVAR and distal bare-metal stent implantation to re-open the true lumen and to prevent distal stent-induced new entry. However, this study reports the challenges of this approach with a high rate of bare-metal stent fractures during the follow-up. The fractures that occurred at the site of vertical nitinol bridges led to the dissection membrane ruptures and the reperfusion of the false lumen with consecutive dilatation. A close follow-up is mandatory to detect this complication and to treat the patients with TEVAR extension.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com