New Preloaded System for Renal and Visceral Arteries in Fenestrated Endografting

Author:

Gallitto Enrico1ORCID,Faggioli Gianluca1ORCID,Spath Paolo1ORCID,Feroldi Francesca M.1ORCID,Pini Rodolfo1ORCID,Logiacco Antonino1,Sufali Gemmi1ORCID,Caputo Stefania1,Gargiulo Mauro1

Affiliation:

1. Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, IRCCS Sant’Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy

Abstract

Aim/Background: The New Preloaded System (NPS) for renal/visceral arteries (TVVs) is an emerging technology in fenestrated endografting (FEVAR) that allows TVVs cannulation and stenting through the same access of the endograft main body. However, only few preliminary experiences are currently available in the literature. The aim of this study is to report the outcomes of NPS-FEVAR in juxta/para-renal (J/P-AAAs) and thoracoabdominal (TAAAs) aneurysms repair. Methods: This is a prospective ( NCT05224219), single-center/observational study of patients submitted to NPS-FEVAR for J/PAAAs and TAAAs between 2019 and 2022 (July). Definitions and outcomes were evaluated according to the current SVS-reporting standard. Technical success (TS) and TS preloaded related, spinal cord ischemia (SCI), and 30-day mortality were assessed as early endpoints. Survival, freedom from reinterventions (FFRs), and freedom from TTVs-instability (FFTVVs-instability) were analyzed during follow-up. Results: Among 157 F/B-EVAR cases, 74 (47%) NPS-FEVAR were planned and enrolled in the study [48 (65%) J/P-AAAs; 26 (35%) TAAAs]. The main indication for NPS-FEVAR was the presence of a hostile iliac axis (54%–73%) or the necessity of expeditious pelvic/lower-limb reperfusion for SCI prevention in TAAAs (20%–27%). Overall, 292 TVVs were accommodated by 289 fenestrations and 3 branches; 188 of 289 (65%) fenestrations were preloaded. NPS-FEVAR configuration was from “below” and “from below to above” in 28 (38%) and 46 (62%) cases, respectively. TS and TS preloaded system-related was 96% (71/74) and 99% (73/74), respectively. Target visceral vessels patency at the completion angiography was 99% (290/292). Failures were 2 renal arteries loss and 1 massive bleeding from a percutaneous closure system breakage. The latter patient developed postoperative multiorgans failure and died on the fifth postoperative day, causing only 30-day/in-hospital mortality (1.3%). One (1.3%) patient with a JAAA and preoperative bilateral occlusion of the hypogastric arteries suffered SCI. The median follow-up was 14 (IQR: 8) months. The estimated 3-year survival was 91% with no aneurysm-related mortality during follow-up. The estimated 3-year FFR and FFTVVs-instability were 85 and 92%, respectively. Conclusion: New preloaded system FEVAR is a safe and effective option in the treatment of J/PAAAs and TAAAs in the presence of hostile iliac access or to guarantee an expeditious pelvic/lower limb reperfusion, leading to satisfactory results in terms of TS, early and mid-term clinical outcomes. Clinical Impact New preloaded system for fenestrated and branched endografting allows to increase the feasibility of the advanced endovascular aortic repair in challenging iliac access, thoracoabdominal aneurysm repair and reduce difficulties in target visceral vessels cannulation.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3