Predicting Features of Visceral Stent Failure in Fenestrated Endovascular Aortic Aneurysm Repair

Author:

Mancuso Enrico1ORCID,Bootun Roshan1ORCID,Stather Philip W.12ORCID,Crawford Michael3,Delbridge Michael1,Tariq Ali Mohammad3,Al-Jundi Wissam1

Affiliation:

1. Department of Vascular Surgery, Norfolk and Norwich University Hospital, Norwich, UK

2. Norwich Medical School, University of East Anglia, Norwich, UK

3. Norfolk Centre for Interventional Radiology, Norfolk and Norwich University Hospital, Norwich, UK

Abstract

Purpose: Visceral stents in fenestrated endovascular aortic repair (FEVAR) have a significant risk of complications and carry a considerable burden of reinterventions. The aim of this study is to identify preoperative and intraoperative predictors of visceral stent failure. Materials: A retrospective review of 75 consecutive FEVARs in a single center from 2013 to 2021 was undertaken. Data on mortality, stent failure, and reintervention pertaining to 226 visceral stents were collected. Methods: Anatomical features including aortic neck angulation, aneurysm diameter, and angulation of target viscerals were obtained from preoperative computed tomography (CT) scans. Stent oversizing and intraprocedural complications were recorded. Postoperative CT scans were analyzed to determine the length of cover of target vessels. Results: Only bridging stents through fenestrations to visceral vessels were considered; 28 (37%) cases had 4 visceral stents, 24 (32%) had 3, 19 (25%) had 2, 4 (5%) had 1. Thirty day mortality was 8%, a third of which was related to visceral stent complications. Intraprocedural complexity was documented during the cannulation of 8 (3.5%) target vessels, with a technical success rate of 98.7%. A significant endoleak or visceral stent failure was identified in 22 stents (9.8%) postoperatively, of which 7 (3%) had in-patient reintervention within 30 days. Further reinterventions at 1, 2, and 3 years were 12 (5.4%), 2 (1%), and 1 (0.4%), respectively. Most reinterventions were for renal stents (n=19, 86%). A smaller stent diameter and a shorter length of visceral stent were significant predictors of failure. No other anatomical feature or stent choice was found to be a significant predictor of failure. Conclusions: The modality of visceral stent failures varies, but renal stents with a smaller diameter and/or shorter length are more likely to fail over time. Their complications and reinterventions are common and carry a significant burden; therefore, close surveillance must be continued long term. Clinical impact With this work we share the methodology adopted at our centre to treat juxtarenal aneurysm with FEVAR. Thanks to this detailed review of anatomical and technical features we provide guidance for endovascular surgeons to face hostile aneurysm with peculiar visceral vessels anatomy. With our findings will also motivate industries in their attempt to produce improved technologies able to overcome issues identified in this paper.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3