Fenestrated Aortic Aneurysm Repair in Patients Treated Inside Versus Outside of Instructions for Use

Author:

Stern Jordan R.1ORCID,Deslarzes-Dubuis Céline1,Tran Kenneth1,Lee Jason T.1

Affiliation:

1. Division of Vascular and Endovascular Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA, USA

Abstract

Objectives: The aim of this study was to compare outcomes of patients treated with the Cook Zenith Fenestrated (ZFEN) device for juxtarenal aortic aneurysms inside versus outside the IFU. Methods: We retrospectively reviewed our institutional ZFEN database for cases performed between 2012 and 2018, with analysis performed in 2020 in order to report midterm outcomes. The cohort was stratified based on treatment inside (IFU group) and outside (non-IFU group) the IFU for criteria involving the proximal neck: neck length 4 to 14 mm, neck diameter 19 to 31 mm, and neck angulation ≤45°. Patients with thoracoabdominal aneurysms or concurrent chimney grafting were excluded. The primary outcomes in question were mortality, type 1a endoleak, and reintervention. Univariate and multivariate analyses were performed to determine associations between adherence to IFU criteria and outcomes. Results: We identified 100 consecutive patients (19% female, mean age 73.6 years) for inclusion in this analysis. Mean follow-up was 21.6 months. Fifty-four patients (54%) were treated outside the IFU because of inadequate neck length (n=48), enlarged neck diameter (n=10), and/or excessive angulation (n=16). Eighteen patients were outside IFU for two criteria, and one patient was outside IFU for all three. Non-IFU patients were exposed to higher radiation doses (3652 vs 5445 mGy, p=0.008) and contrast volume (76 vs 95 mL, p=0.004). No difference was noted between IFU and non-IFU groups for 30-day mortality (0% vs 3.7%, p=0.18), or type 1a endoleak (0% vs 1.9%, p=0.41). Reintervention was also similar between cohorts (13% vs 27.8%, p=0.13). Being outside IFU for neck diameter or length was each borderline significant for higher reintervention on univariate analysis (p=0.05), but this was not significant on multivariate Cox proportional hazard modeling (HR 1.82 [0.53–6.25]; 2.03 [0.68–7.89]), respectively. No individual IFU deviations were associated with the primary outcomes on multivariate analysis, nor being outside IFU for multiple criteria. Conclusions: Patients with juxtarenal aortic aneurysms may be treated with the ZFEN device with moderate deviations from the IFU. While no differences were seen in mortality or proximal endoleak, larger studies are needed to examine the potential association between IFU nonadherence and reinterventions and close follow-up is warranted for all patients undergoing such repair.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3