Polymeric Surface Modifications of Tantalum Stents

Author:

Fontaine Arthur B.,Koelling Kurt1,Passos Susan Dos2,Cearlock Jody3,Hoffman Randy4,Spigos Dimitrios G.3

Affiliation:

1. Department of Engineering, Ohio State University, Columbus

2. CV Rad Inc., Upper Arlington, Ohio

3. Department of Radiology, Ohio State University Hospitals, Baltimore, Maryland, USA

4. Department of Radiology, The Johns Hopkins Medical Center, Baltimore, Maryland, USA

Abstract

Purpose: To compare two kinds of polymer-coated tantalum stents with bare tantalum stents (control) to determine if the coatings can improve thromboresistance. Methods: Twenty-seven Fontaine-Dake stents were balloon expanded in three 8-mm × 80-cm.polytetrafluoroethylene (PTFE) grafts; 9 stents were bare tantalum (T); 9 were coated with polyetherurethane (PL); and 9 were coated with parylene (PA). There were 9 stents placed in each graft as follows: 3 tantalum, 3 polyetherurethane, and 3 parylene. In swine whose platelets had been radiolabeled with indium 111, the ends of each stented graft were connected to 14F femoral and venous sheaths to create an ex vivo fistula. Each graft was exposed to blood for 30, 60, and 120 minutes. At the end of each test period, the stented grafts were disconnected from the sheaths, flushed with saline until clear, and then flushed with formalin. The stents were removed from the grafts, and a radionuclide well counter recorded radionuclide counts from each stent type at each period of blood contact. These values were converted to platelet density per 1000 mUm2. Stents were then photographed and scanned with electron microscopy (EM) for qualitative analysis. Possible significant differences in platelet adhesion with the three types of stents (both between stent groups and within stent groups) were examined using a two-tailed Student's f-test. Results: There were significantly fewer platelets adsorbed on PA versus T at all time periods (p < 0.005); on PL versus T at 60 and 120 minutes (p < 0.005); and on PA versus PL at 30 and 120 minutes (p < 0.0005). There was no significant difference in platelet density within each stent group (p = 0.1). Mean platelet density (number of platelets per 1000 mUm2 ± SD) was as follows: at 30 minutes: T = 1891 ± 965; PL = 373 ± 193; and PA = 27 ± 3; at 60 minutes: T = 6226 ± 1621; PL = 1573 ± 793; and PA = 1185 ± 710; at 120 minutes: T = 5307 ± 591; PL = 3164 ± 318; and PA = 180 ± 100. Gross inspection of the 120-minute groups demonstrated focal areas of thrombus on T, less on PL, and none on PA. Scanning EM demonstrated extensive platelet accumulation covering T at all time periods, less on PL, and even less on PA. Conclusions: Polymeric surface modification of tantalum stents with parylene and/or polyetherurethane can improve the acute thromboresistance of these devices; parylene appears to be the more thromboresistant of the two coatings.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3