Device-Specific Resistance to in Vivo Displacement of Stent-Grafts Implanted with Maximum Iliac Fixation

Author:

Murphy Erin H.1,Johnson Eric D.1,Arko Frank R.1

Affiliation:

1. Division of Vascular Surgery, UT Southwestern Medical Center, Dallas, Texas, USA

Abstract

Purpose: To compare the in vivo device-specific downward displacement force of various externally supported endografts implanted with maximum iliac fixation. Methods: Twenty female sheep had aneurysms created with a graft patch in the infrarenal aorta. In 12 animals, a fully supported modular bifurcated stent-graft [AneuRx (n=4), Talent (n=4), or Zenith (n=4)] was deployed; in the other 8, a bifurcated aortic graft was surgically anastomosed to the infrarenal aorta. All grafts were displaced in vivo by applying downward traction to a guidewire brought out both femoral arteries. The peak force to cause initial stent-graft migration or disruption of the sutured anastomosis was recorded and compared. Results: There was no difference in animal size, aortic neck diameter or length, aneurysm size, or iliac artery diameter for animals receiving the AneuRx, Talent, or Zenith stent-grafts and those undergoing surgical repair. The mean length of iliac fixation was 31.0±0.3 mm, 30.8±0.5 mm, and 31.3±0.6 mm for the AneuRx, Talent, and Zenith devices, respectively (p=NS). Peak force to initiate migration was 30.2=5.5 N (range 25–38) for the AneuRx, 44.8±5.5 N (range 40–53) for the Talent, 46.7±5.4 N (range 38–55) for the Zenith, and 40.6±7.5 N (range 31–50) for the surgical anastomosis (p=0.01). There was no difference detected in the peak force to initiate migration between the suprarenally affixed Talent and Zenith stent-grafts and the surgical anastomosis (p=0.55). Conclusion: Devices with a suprarenal component require significantly greater force to cause downward displacement compared to infrarenal devices. The force required to displace a suprarenal device with maximal iliac fixation was equivalent to the force required to disrupt a surgical anastomosis.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Animal Models in the Research of Abdominal Aortic Aneurysms Development;Physiological Research;2017-12-16

2. Animal Models Used to Explore Abdominal Aortic Aneurysms: A Systematic Review;European Journal of Vascular and Endovascular Surgery;2016-10

3. Livestock in biomedical research: history, current status and future prospective;Reproduction, Fertility and Development;2016

4. Angiographic Anatomy of External Iliac Arteries in the Sheep;Anatomia, Histologia, Embryologia;2015-12-17

5. Endovascular Management of Aortic Aneurysmal and Stenotic Disease;Textbook of Cardiovascular Intervention;2013-09-13

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3