Rotational Atherectomy Plus Drug-Coated Balloon Angioplasty for the Treatment of Total In-Stent Occlusions in Iliac and Infrainguinal Arteries

Author:

Milnerowicz Artur1,Milnerowicz Aleksandra1ORCID,Kuliczkowski Wiktor2,Protasiewicz Marcin2

Affiliation:

1. Department of Vascular, General and Transplantation Surgery, Medical University of Wrocław, Poland

2. Department and Clinic of Cardiology, Medical University of Wrocław, Poland

Abstract

Purpose: To analyze the long-term outcomes of a hybrid treatment method combining rotational atherectomy with drug-coated balloon (DCB) angioplasty in patients with total in-stent occlusion in the iliac and/or infrainguinal arteries. Materials and Methods: Between April 2014 and June 2017, 74 consecutive patients (mean age 66.7±9.7 years; 49 men) with total occlusion of a previously implanted stent underwent endovascular recanalization using the Rotarex system and DCB angioplasty. Half (37, 50%) of the patients had critical limb ischemia (CLI), and 30 (41%) of the procedures were performed in emergency. Mean lesion length was 22±15 cm. Results: Overall procedure success was achieved in 73 (98.6%) patients. Six (8.1%) CLI patients developed distal embolism that responded to thrombolysis. Three (4.1%) dissections did not require treatment, while 1 (1.4%) perforation necessitated stent-graft implantation. In all, 33 (44.6%) patients had an additional stent implanted, mainly due to a suboptimal outcome (n=28) or complications (n=5 including the stent-graft). The restenosis rate assessed by duplex ultrasound at 12 months was 20.5% (15/73); 4 (5.5%) patients underwent target lesion revascularization. Recurrent restenosis was more frequent in patients with Rutherford category 5 ischemia (p=0.005), in emergency procedures (p=0.021), after extensive procedures involving 3 independent vessel segments (p=0.016), and if a complication arose during the procedure (p<0.001). In multivariate analysis, only occurrence of a procedural complication was an independent predictor of recurrent restenosis at 1 year (OR 63.3, 95% CI 5.7 to 701.5). Conclusion: These findings imply that rotational atherectomy and DCB angioplasty may provide satisfactory outcomes in the treatment of total in-stent occlusion, with a satisfactory recurrent restenosis rate at 12 months.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3