Expanded Suitability of Ruptured Abdominal Aortic Aneurysms for Total Endovascular Repair Using the Endurant Endograft and Heli-FX EndoAnchors

Author:

Reyes Valdivia Andrés1ORCID,Álvarez Marcos Francisco2,Duque Santos África1,Ocaña Guaita Julia1,Gandarias Zúñiga Claudio1

Affiliation:

1. Department of Vascular and Endovascular Surgery, Ramón y Cajal University Hospital, Madrid, Spain

2. Department of Vascular and Endovascular Surgery, Complexo Hospitalario A Coruña, Spain

Abstract

Purpose: To assess if the suitability of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs) can be expanded by combining the Endurant stent-graft with the Heli-FX EndoAnchors. Materials and Methods: Contrast-enhanced computed tomography (CT) scans of 90 patients (mean age 73.2±9 years; 87 men) with RAAA admitted between January 2014 and January 2018 in 2 tertiary care centers were analyzed in a 3-dimensional workstation. Anatomical features of the aneurysms according to the instructions for use (IFU) for the Endurant endograft were evaluated and expansion of treatment with Heli-FX EndoAnchors was assessed. Results: Neck length <10 mm was present in 41 (45.6%) patients; 5 had neck diameters outside the IFU and 45 (50.0%) had conical necks. Thrombus and calcium were absent in 63 (70.0%) and 73 (81.1%), respectively. In the study cohort, 44 (48.9%) patients met all the neck criteria, although overall IFU compliance was found in only 35 (38.9%) patients due to iliac-related issues in 21 patients. The adjunctive use of EndoAnchors in the entire study group would enhance the therapeutic range to an additional 24 patients, 8 of whom would need an associated iliac procedure. This represents an expansion of the total EVAR approach from 48.9% to 75.6% of cases if some iliac issues are overcome and from 38.9% to 56.7% without correcting iliac deficiencies. Conclusion: The main reason of being unfit for endovascular treatment in this series was neck length <10 mm. Based on this analysis, nearly 40% of RAAA patients would have been candidates for EVAR based on the IFU neck criteria for the Endurant stent-graft. This suitability could be nearly doubled with the use of EndoAnchors and correction of unsuitable iliac anatomy. The use of EndoAnchors has the potential to offer a significant benefit in the endovascular treatment of RAAA patients.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3