Pancreatic cyst fluid glucose: a rapid on-site diagnostic test for mucinous cysts

Author:

Zamir Efrat1ORCID,Zelnik Yovel Dana23ORCID,Scapa Erez24,Shnell Mati24,Bar Nir24,Bar Yishay Iddo24,Ziv-Baran Tomer5,Younis Fadi24,Phillips Adam24,Lubezky Nir26,Shibolet Oren24,Ben-Ami Shor Dana24

Affiliation:

1. Sackler Faculty of Medicine, Tel Aviv University, P.O.B 39040, Ramat Aviv, Tel Aviv 69978, Israel

2. Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel

3. The Kamila Gonczarowski Institute of Gastroenterology and Liver Diseases, Shamir (Assaf Harofeh) Medical Center, Zerifin, Israel

4. Gastroenterology and Liver Disease, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel

5. School of Public Health, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel

6. Unit of Liver Surgery, Department of Surgery, Tel Aviv Medical Center, Tel Aviv, Israel

Abstract

Background: Pancreatic cystic fluid (PCF) analysis is frequently used for cyst diagnosis with carcinoembryonic antigen (CEA) being the most accepted biomarker. Low glucose levels in PCF were previously suggested as a marker for mucinous cysts. A bed-side glucometer is a point-of care, immediate, simple, and cheap method which requires a small volume of PCF. Objectives: The aim of our study was to identify the optimal glucose cut-off level for identifying mucinous cysts, evaluate the diagnostic accuracy of glucose compared to CEA, and validate glucometry against reference laboratory biochemical analysis. Design: A single-center prospective cohort study. Methods: Consecutive patients aged 18 and older, who underwent pancreatic cyst evaluation, at the Tel Aviv Medical Center between 2016 and 2021 were analyzed. Cyst type was defined based on clinical, laboratory, and radiologic findings. Glucose was measured using laboratory biochemical analysis and two glucometers. Receiver operating characteristic analysis derived sensitivity, specificity, and accuracy were calculated and McNemar test was used to compare between methods. Results: One hundred and one PCF samples were evaluated. The areas under the receiver operating characteristics curve for identifying mucinous cysts using glucometer, glucose laboratory, and their combination were 0.88 ( p < 0.001), 0.92 ( p < 0.001), and 0.93 ( p < 0.001), respectively. A glucose level of 87 mg/dL was identified as the optimal laboratory glucose threshold value to detect mucinous cyst with a sensitivity of 90.9%, specificity of 83.3%, and accuracy of 89.3, higher in comparison to cyst fluid CEA. Furthermore, PCF glucose levels had the strongest association with mucinous cysts. Conclusion: Our findings suggest that PCF glucose level is more accurate than CEA for the diagnosis of mucinous cysts. Glucometry glucose level assessment demonstrated an excellent correlation with laboratory glucose measurements and may become a useful diagnostic test.

Publisher

SAGE Publications

Subject

Gastroenterology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3